3. SIGNALS AND WIRING
3 - 11
3.3.3 Wiring CNP1, CNP2, and CNP3
POINT
For the wire sizes used for wiring, refer to section 11.5.
(1) Connector
Servo amplifier
CNP1
CNP2
CNP3A
CNP3B
CNP3C (Note)
Note. For the MR-J4 3-axis servo amplifier
Table 3.1 Connector and applicable wire
Connector Receptacle
assembly
Applicable wire
size
Stripped length
[mm]
Open tool
Manufacturer
CNP1
03JFAT-SAXGFK-43
AWG 16 to 14
11.5
J-FAT-OT-EXL (big size
side)
JST
CNP2
06JFAT-SAXYGG-F-
KK
AWG 16 to 14
9
J-FAT-OT-EXL (small size
side)
CNP3A
CNP3B
CNP3C
04JFAT-SAGG-G-KK
AWG 18 to 14
9
J-FAT-OT-EXL (small size
side)
(2) Cable connection procedure
(a) Cable making
Refer to table 3.1 for stripped length of cable insulator. The appropriate stripped length of cables
depends on their type, etc. Set the length considering their status.
Insulator
Core
Stripped length
Twist strands slightly and straighten them as follows.
Loose and bent strands
Twist and straighten
the strands.
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......