5. PARAMETERS
5 - 13
5.2 Detailed list of parameters
POINT
"x" in the "Setting digit" columns means which digit to set a value.
5.2.1 Basic setting parameters ([Pr. PA_ _ ])
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PA01 **STY Operation
mode
Select an operation mode.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
For manufacturer setting
0h
_ _ x _
Operation mode selection
0: Standard control mode
1: Fully closed loop control mode
4. Linear servo motor control mode
6: DD motor control mode
Setting other than above will result in [AL. 37 Parameter
error]. The fully closed loop system is available for the MR-
J4W2-_B servo amplifiers of which software version is A3
or above. It will not be available with MR-J4W3-_B servo
amplifiers.
For MR-J4W2-0303B6 servo amplifiers, this digit cannot be
used other than the initial value.
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
Operation mode selection
To change this digit, use an application software "MR-
J4(W)-B mode selection". When you change it without the
application, [AL. 3E Operation mode error] will occur.
Set the digit as common setting.
0: J3 compatibility mode
1: J4 mode
1h
PA02 **REG Regenerative
option
Select a regenerative option.
Incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, [AL. 37
Parameter error] occurs.
Refer to Name
and function
column.
Common
Setting
digit
Explanation
Initial
value
_ _ x x
Regenerative option selection
00: Regenerative option is not used. (Built-in regenerative
resistor is used.)
0B: MR-RB3N
0D: MR-RB14
0E: MR-RB34
For MR-J4W2-0303B6 servo amplifiers, this digit cannot be
used other than the initial value.
00h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
Содержание MR-J4W2
Страница 9: ...A 8 MEMO ...
Страница 17: ...8 MEMO ...
Страница 31: ...1 FUNCTIONS AND CONFIGURATION 1 14 MEMO ...
Страница 95: ...4 STARTUP 4 20 MEMO ...
Страница 169: ...6 NORMAL GAIN ADJUSTMENT 6 20 MEMO ...
Страница 201: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 32 MEMO ...
Страница 213: ...8 TROUBLESHOOTING 8 12 MEMO ...
Страница 219: ...9 OUTLINE DRAWINGS 9 6 MEMO ...
Страница 229: ...10 CHARACTERISTICS 10 10 MEMO ...
Страница 295: ...13 USING STO FUNCTION 13 14 MEMO ...
Страница 327: ...14 USING A LINEAR SERVO MOTOR 14 32 MEMO ...
Страница 371: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Страница 521: ...APPENDIX App 38 ...
Страница 537: ...MEMO ...
Страница 541: ......