16 FULLY CLOSED LOOP SYSTEM
16.3 Operation and functions
h)
Polarity
For address increasing direction in the servo motor CCW, it is indicated as "+" and for address
decreasing direction in the servo motor CCW, as "-".
i)
Z phase pass status
If the fully closed loop system is "Disabled", the Z-phase pass status of the servo motor encoder is
displayed. If the fully closed loop system is "Enabled" or "Semi closed loop control/fully closed loop
control switching", the Z-phase pass status of the load-side encoder is displayed.
j)
Fully closed loop changing
device
Only if the fully closed loop system is "Semi closed loop control/fully closed loop control switching", the
device is displayed.
The state of the semi closed loop control/fully closed loop control switching signal and the inside state
during selection are displayed.
k)
Parameter (Feedback pulse
electronic gear)
The feedback pulse electronic gears ([Pr. PE04], [Pr. PE05], [Pr. PE34], and [Pr. PE35]) are displayed/
set for servo motor encoder pulses in this parameter.
Page 524 Setting of feedback pulse electronic gear
l)
Parameter (Dual feedback filter)
The band of [Pr. PE08 Fully closed loop dual feedback filter] is displayed/set in this parameter.
m)
Parameter (fully closed loop
function)
The parameter for the fully closed loop control is displayed or set.
Click "Parameter setting" to display the "Fully closed loop control - Basic" window.
1) Fully closed loop function selection ([Pr. PE01])
Select "Always valid" or "Change according to fully closed selection signal" here.
2) Feedback pulse electronic gear ([Pr. PE04], [Pr. PE05], [Pr. PE34], [Pr. PE35])
Set the feedback pulse electronic gear.
3) Load-side encoder cable communication method selection ([Pr. PC26])
Select a load-side encoder cable to be connected to the CN2L connector.
4) Selection of encoder pulse count polarity ([Pr. PC27])
Select a polarity of the load-side encoder information.
5) Selection of A/B/Z-phase input interface encoder Z-phase connection judgment function ([Pr.
PC27])
Select the non-signal detection status for the pulse train signal from the A/B/Z-phase input interface
encoder used as a linear encoder or load-side encoder.
This function is enabled only when you use an A/B/Z-phase input interface encoder.
Symbol Name
Explanation
Unit
1)
2)
3)
4)
5)