284
8 TROUBLESHOOTING
8.2 Alarm list
3A
Inrush current suppression
circuit error
3A.1
Inrush current suppression error
EDB
3D
Parameter setting error for
driver communication
3D.1
Parameter combination error for driver
communication on slave
DB
3D.2
Parameter combination error for driver
communication on master
DB
3E
Operation mode error
3E.1
Operation mode error
DB
3E.6
Operation mode switch error
DB
3E.8
MR-D30 combination error
DB
42
Servo control error
(for linear servo motor and
direct drive motor)
42.1
Servo control error by position deviation
EDB
42.2
Servo control error by speed deviation
EDB
42.3
Servo control error by torque/thrust deviation
EDB
Fully closed loop control error
(for fully closed loop control)
42.8
Fully closed loop control error by position deviation
EDB
42.9
Fully closed loop control error by speed deviation
EDB
42.A
Fully closed loop control error by position deviation
during command stop
EDB
45
Main circuit device overheat
45.1
Main circuit device overheat error 1
SD
45.2
Main circuit device overheat error 2
SD
46
Servo motor overheat
46.1
Abnormal temperature of servo motor 1
SD
46.2
Abnormal temperature of servo motor 2
SD
46.3
Thermistor disconnected error
SD
46.4
Thermistor circuit error
SD
46.5
Abnormal temperature of servo motor 3
DB
46.6
Abnormal temperature of servo motor 4
DB
47
Cooling fan error
47.1
Cooling fan stop error
SD
47.2
Cooling fan speed reduction error
SD
50
Overload 1
50.1
Thermal overload error 1 during operation
SD
50.2
Thermal overload error 2 during operation
SD
50.3
Thermal overload error 4 during operation
SD
50.4
Thermal overload error 1 during a stop
SD
50.5
Thermal overload error 2 during a stop
SD
50.6
Thermal overload error 4 during a stop
SD
51
Overload 2
51.1
Thermal overload error 3 during operation
DB
51.2
Thermal overload error 3 during a stop
DB
52
Error excessive
52.1
Excess droop pulse 1
SD
52.3
Excess droop pulse 2
SD
52.4
Error excessive during 0 torque limit
SD
52.5
Excess droop pulse 3
EDB
54
Oscillation detection
54.1
Oscillation detection error
EDB
56
Forced stop error
56.2
Over speed during forced stop
EDB
56.3
Estimated distance over during forced stop
EDB
56.4
Forced stop start error
EDB
61
Operation error
61.1
Point table setting range error
DB
63
STO timing error
63.1
STO1 off
DB
63.2
STO2 off
DB
63.5
STO by functional safety unit
DB
64
Functional safety unit setting
error
64.1
STO input error
DB
64.2
Compatibility mode setting error
DB
64.3
Operation mode setting error
DB
No.
Name
Detail
No.
Detail name
Stop
method
*2*3
Alarm deactivation
Alarm
reset
CPU
reset
Cycling
the
power
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Страница 645: ......