578
APPX
Appendix 4 Compliance with global standards
Installation direction and clearances
To adapt your machine using MR-J4-03A6 or MR-J4W2-0303B6 to IEC/EN 60950-1, either supply the amplifier with a power
supply complying with the requirement of 2.5 stated in IEC/EN 60950-1 (Limited Power Source), or cover the amplifier and
motors connected to the outputs with a fire enclosure.
*1 For 11 kW to 22 kW servo amplifiers, the clearance between the bottom and ground will be 120 mm or more.
*2 When mounting MR-J4-500_, maintain a minimum clearance of 25 mm on the left side.
Electrical Installation and configuration diagram
CAUTION
• The devices must be installed in the specified direction. Not doing so may cause a malfunction.
• Mount the servo amplifier on a cabinet which meets IP54 in the correct direction to maintain pollution degree 2.
• The regenerative resistor supplied with 11 kW to 22 kW servo amplifiers does not have a protective cover. Touching the resistor (including wiring/screw hole
area) may cause a burn injury and electric shock. Even if the power was shut-off, be careful until the bus voltage discharged and the temperature decreased
because of the following reasons.
It may cause a burn injury due to very high temperature without cooling.
It may cause an electric shock due to charged capacitor of the servo amplifier.
WARNING
• Turn off the molded-case circuit breaker (MCCB) to avoid electrical shocks or damages to the product before starting the installation or wiring.
CAUTION
• The installation complies with IEC/EN 60204-1. The voltage supply to machines must be 20 ms or more of tolerance against instantaneous power failure as
specified in IEC/EN 60204-1.
• Connecting a servo motor for different axis to U, V, W, or CN2_ of the servo amplifier may cause a malfunction.
• Securely connect the cables in the specified method and tighten them with the specified torque. Otherwise, the servo motor may operate unexpectedly.
10 mm or
more
80 mm or longer
for wiring
10 mm or
more
*2
Top
Bottom
40 mm or
more
*1
40 mm or
more
Cabinet
Servo amplifier
Servo amplifier
Cabinet
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...