7 SPECIAL ADJUSTMENT FUNCTIONS
7.3 Tough drive function
271
7
Instantaneous power failure time of the control circuit power supply < [Pr. PF25 SEMI-
F47 function - Instantaneous power failure detection time]
Operation status differs depending on how bus voltage decreases.
■
When the bus voltage decreases to the undervoltage level or lower within instantaneous
power failure time of control circuit power supply
[AL. 10 Undervoltage] occurs when the bus voltage decreases to the undervoltage level or lower regardless of the enabled
instantaneous power failure tough drive.
*1 For the undervoltage level, refer to "[AL. 10.2 Voltage drop in the main circuit power] will occur when bus voltage is as follows." in
"Parameter setting" below.
[Pr. PF25]
Instantaneous power failure time of the control circuit power supply
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Control circuit
power supply
Bus voltage
Undervoltage level
*1
ALM
(Malfunction)
MTTR
(During tough drive)
MBR
(Electromagnetic
brake interlock)
Base circuit
WNG
(Warning)
ON (Energization)
OFF (Power failure)