180
5 PARAMETERS
5.1 Parameter list
Positioning control parameters ([Pr. PT_ _ ])
No.
Symbol
Name
Initial
value
Unit
Operation mode
Standard Full.
Lin.
DD
PT01
For manufacturer setting
0300h
PT02
0001h
PT03
0000h
PT04
0000h
PT05
ZRF
Home position return speed
100.00
[r/min]/[mm/s]
PT06
CRF
Creep speed
10.00
[r/min]/[mm/s]
PT07
ZST
Home position shift distance
0
[pulse]
PT08
For manufacturer setting
0
PT09
DCT
Travel distance after proximity dog
0
[pulse]
PT10
ZTM
Stopper type home position return stopper time
100
[ms]
PT11
ZTT
Stopper type home position return torque limit value
15.0
[%]
PT12
For manufacturer setting
0
PT13
100
PT14
0
PT15
LMPL
Software limit +
0000h
[pulse]
PT16
LMPH
0000h
PT17
LMNL
Software limit -
0000h
[pulse]
PT18
LMNH
0000h
PT19
For manufacturer setting
0000h
PT20
0000h
PT21
0000h
PT22
0000h
PT23
0
PT24
0
PT25
0
PT26
0000h
PT27
0000h
PT28
8
PT29
*TOP3
Function selection T-3
0000h
PT30
For manufacturer setting
0000h
PT31
0000h
PT32
0000h
PT33
0000h
PT34
0000h
PT35
0000h
PT36
0000h
PT37
10
PT38
0000h
PT39
100
PT40
0
PT41
ORP
Home position return inhibit function selection
0000h
PT42
For manufacturer setting
0
PT43
0
PT44
0000h
PT45
HMM
Home position return type
37