192
5 PARAMETERS
5.2 Detailed list of parameters
Gain/filter setting parameters ([Pr. PB_ _ ])
No./symbol/
name
Setting
digit
Function
Initial
value
[unit]
PB01
FILT
Adaptive tuning
mode (adaptive
filter
)
_ _ _ x
Filter tuning mode selection
Set the adaptive tuning.
Select the adjustment mode of the machine resonance suppression filter 1.
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
For manufacturer setting
0h
_ x _ _
0h
x _ _ _
0h
PB02
VRFT
Vibration
suppression control
tuning mode
(advanced vibration
suppression control
)
_ _ _ x
Vibration suppression control 1 tuning mode selection
Select the tuning mode of the vibration suppression control 1.
Page 254 Advanced vibration suppression control II
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ _ x _
Vibration suppression control 2 tuning mode selection
Select the tuning mode of the vibration suppression control 2. To enable the digit, set "Vibration suppression
mode selection" to "3 inertia mode (_ _ _ 1)" in [Pr. PA24].
Page 254 Advanced vibration suppression control II
0: Disabled
1: Automatic setting
2: Manual setting
0h
_ x _ _
For manufacturer setting
0h
x _ _ _
0h
PB04
FFC
Feed forward gain
Set the feed forward gain.
When the setting is 100%, the droop pulses during operation at constant speed will be almost 0. When the
super trace control is enabled, constant speed and uniform acceleration/deceleration droop pulses will be
almost 0. However, sudden acceleration/deceleration will increase the overshoot. As a guideline, when the
feed forward gain setting is 100%, set 1 s or more for the acceleration time constant to the rated speed.
Setting range: 0 to 100
0 [%]
PB06
GD2
Load to motor
inertia ratio/load to
motor mass ratio
Set a load to motor inertia ratio or load to motor mass ratio.
Setting a value considerably different from the actual load moment of inertia or load mass may cause an
unexpected operation such as an overshoot.
The setting of this parameter will be automatic or manual depending on the setting of [Pr. PA08]. Refer to the
following table for details. When the parameter is set to automatic, the value will vary between 0.00 and
100.00.
Setting range: 0.00 to 300.00
7.00 [times]
Pr. PA08
This parameter
Automatic setting
_ _ _ 1: (Auto tuning mode 1)
Manual setting
_ _ _ 3 (Manual mode)
_ _ _ 4: (2 gain adjustment mode 2)
_ _ _ 0 (2 gain adjustment mode 1 (interpolation mode))
_ _ _ 2: (Auto tuning mode 2)