11.12 Power factor improving AC reactors
11.12
Power factor improving AC reactors
The following shows the advantages of using power factor improving AC reactor.
• It improves the power factor by increasing the form factor of the servo amplifier's input current.
• It decreases the power supply capacity.
• The input power factor is improved to about 80%.
When using power factor improving AC reactors for two servo amplifiers or more, be sure to connect a power factor improving
AC reactor to each servo amplifier. If one unit of power factor improving reactor is used for multiple servo amplifiers, the power
factor cannot be improved sufficiently unless all servo amplifiers are operated.
100 V class/200 V class
Servo amplifier
Power factor
improving
AC reactor
Dimensions [mm]
Terminal
size
Mass [kg]
W
W1
H
D1
D2
d
MR-J4-10GF(-RJ)
MR-J4-20GF(-RJ)
MR-J4-10GF1(-RJ)
FR-HAL-0.4K
104
84
99
72
51
40
M5
M4
0.6
MR-J4-40GF(-RJ)
MR-J4-20GF1(-RJ)
FR-HAL-0.75K
104
84
99
74
56
44
M5
M4
0.8
MR-J4-60GF(-RJ)
MR-J4-70GF(-RJ)
MR-J4-40GF1(-RJ)
FR-HAL-1.5K
104
84
99
77
61
50
M5
M4
1.1
MR-J4-100GF(-RJ)
(3-phase power
supply input)
FR-HAL-2.2K
40
115
77
71
57
M6
M4
1.5
MR-J4-100GF(-RJ)
(1-phase power
supply input)
MR-J4-200GF(-RJ)
(3-phase power
supply input)
FR-HAL-3.7K
40
115
83
81
67
M6
M4
2.2
MR-J4-200GF(-RJ)
(1-phase power
supply input)
FR-HAL-5.5K
40
115
83
81
67
M6
M4
2.3
4-d mounting hole
(Varnish is removed from front right
mounting hole (face and back side).)
*1
Terminal layout
R X
Z
S Y T
W or less
*2
W1
D1
D2
H
D or less
Y
Z
S
T
Y
Z
S
T
MC
MCCB
MC
MCCB
FR-HAL
Servo amplifier
3-phase 200 V class
X
R
L1
L2
L3
3-phase
200 V AC to
240 V AC
FR-HAL
Servo amplifier
1-phase 200 V class
X
R
L1
L2
1-phase
*3
200 V AC to
240 V AC
L3
L2
Y
Z
S
T
MC
MCCB
FR-HAL
Servo amplifier
1-phase 100 V class
X
R
L1
Unassigned
1-phase
*3
200 V AC to
240 V AC
Содержание MELSERVO-J4 series