126
3 SIGNALS AND WIRING
3.10 Grounding
3.10
Grounding
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on the wiring and
ground cable routing, the servo amplifier may be affected by the switching noise (due to di/dt and dv/dt) of the transistor. To
prevent such a fault, refer to the following diagram and always ground.
To conform to the EMC Directive, refer to "EMC Installation Guidelines".
*1 For the power supply specifications, refer to the following.
Page 30 Servo amplifier standard specifications
WARNING
• Ground the servo amplifier and servo motor securely.
• To prevent an electric shock, always connect the protective earth (PE) terminal (marked
) of the servo amplifier to the protective earth (PE) of the cabinet.
CN1A
Ensure to connect the wire to the
PE terminal of the servo amplifier.
Do not connect the wire directly to
the protective earth of the cabinet.
V
U
M
U
V
W
W
CN2
L11
L1
L2
L3
L21
MC
MCCB
Power
supply
*1
Cabinet
Servo motor
Encoder
Servo amplifier
Line filter
Controller
Protective earth (PE)
Outer
box