14 USING A LINEAR SERVO MOTOR
14.3 Operation and functions
485
14
■
Output signal (DO) forced output
Output signals can be switched on/off forcibly independently of the servo status. This function is used for output signal wiring
check, etc. Perform on the DO forced output screen of MR Configurator2.
■
Program operation
Positioning operation can be performed in two or more operation patterns combined, without using the controller. Use this
operation with the forced stop reset. This operation may be used independently of whether the servo is on or off and whether
the controller is connected or not.
Perform on the program operation screen of MR Configurator2. For full information, refer to Help of MR Configurator2.
Operation procedure
1.
Turn off the power.
2.
Turn "ON (up)" SW1-1.
Turning "ON (up)" SW1-1 during power-on will not enable the test operation mode.
3.
Turn on the servo amplifier.
When initialization is completed, the display shows the following screen.
4.
Start operation with the personal computer.
Operation
Screen control
Start
Click "Operation start".
Pause
Click "Pause".
Stop
Click "Stop".
Forced stop
Click "Forced stop".
Set SW1-1 to "ON (up)".
1
ON
2
1
ON
2
After 1.6 s
After 0.2 s
Blinking
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Страница 645: ......