172
5 PARAMETERS
5.1 Parameter list
Extension setting parameters ([Pr. PC_ _ ])
No.
Symbol
Name
Initial
value
Unit
Operation mode
Standard Full.
Lin.
DD
PC01
ERZ
Error excessive alarm level
0
[rev]/[mm]
PC02
MBR
Electromagnetic brake sequence output
0
[ms]
PC03
*ENRS
Encoder output pulse selection
0000h
PC04
**COP1
Function selection C-1
0000h
PC05
**COP2
Function selection C-2
0000h
PC06
*COP3
Function selection C-3
0000h
PC07
ZSP
Zero speed
50
[r/min]/[mm/s]
PC08
OSL
Overspeed alarm detection level
0
[r/min]/[mm/s]
PC09
MOD1
Analog monitor 1 output
0000h
PC10
MOD2
Analog monitor 2 output
0001h
PC11
MO1
Analog monitor 1 offset
0
[mV]
PC12
MO2
Analog monitor 2 offset
0
[mV]
PC13
For manufacturer setting
0
PC14
0
PC15
0
PC16
0000h
PC17
**COP4
Function selection C-4
0000h
PC18
*COP5
Function selection C-5
0010h
PC19
*COP6
Function selection C-6
0000h
PC20
*COP7
Function selection C-7
0000h
PC21
*BPS
Alarm history clear
0000h
PC22
For manufacturer setting
0
PC23
0000h
PC24
RSBR
Forced stop deceleration time constant
100
[ms]
PC25
For manufacturer setting
0
PC26
**COP8
Function selection C-8
0000h
PC27
**COP9
Function selection C-9
0000h
PC28
For manufacturer setting
0000h
PC29
*COPB
Function selection C-B
1000h
PC30
For manufacturer setting
0
PC31
RSUP1
Vertical axis freefall prevention compensation amount
0
[0.0001 rev]/
[0.01 mm]
PC32
For manufacturer setting
0000h
PC33
0
PC34
100
PC35
0000h
PC36
0000h
PC37
0000h
PC38
ERW
Error excessive warning level
0
[rev]/[mm]