3 SIGNALS AND WIRING
3.3 Explanation of power supply system
101
3
Wiring CNP1, CNP2, and CNP3
• For the wire sizes used for wiring, refer to the following.
Page 400 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule to each wire insertion hole.
• MR-J4-500GF(-RJ) or more and MR-J4-500GF4(-RJ) or more do not have these connectors.
Use the servo amplifier power connector for wiring CNP1, CNP2, and CNP3.
Connector
■
MR-J4-10GF(-RJ) to MR-J4-100GF(-RJ)
■
MR-J4-200GF(-RJ)/MR-J4-350GF(-RJ)
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
06JFAT-SAXGDK-H7.5
AWG 18 to 14
3.9 mm or shorter
9
J-FAT-OT (N) or J-
FAT-OT
JST
CNP2
05JFAT-SAXGDK-H5.0
CNP3
03JFAT-SAXGDK-H7.5
Connector Receptacle assembly
Applicable wire
Stripped length
[mm]
Open tool
Manufacturer
Size
Insulator OD
CNP1
06JFAT-SAXGFK-XL
AWG 16 to 10
4.7 mm or shorter
11.5
J-FAT-OT-EXL
JST
CNP3
03JFAT-SAXGFK-XL
CNP2
05JFAT-SAXGDK-H5.0
AWG 18 to 14
3.9 mm or shorter
9
CNP2
CNP1
CNP3
Servo amplifier
MR-J4-200GF(-RJ)
Servo amplifier
CNP2
CNP1
CNP3
MR-J4-350GF(-RJ)
Servo amplifier
CNP2
CNP1
CNP3