11 OPTIONS AND PERIPHERAL EQUIPMENT
11.9 Selection example of wires
11.9
Selection example of wires
• To comply with the IEC/EN/UL/CSA standard, use the wires shown in the following section for wiring. To
comply with other standards, use a wire that is complied with each standard.
• For the selection example of when the MR-J4-_GF-RJ servo amplifier is used with the DC power supply
input, refer to the following.
Page 566 Selection example of wires
• Selection conditions of wire size are as follows.
Construction condition: Single wire set in midair
Wire length: 30 m or less
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
5) Power regeneration converter lead
Power regeneration
converter
N-
3) Regenerative option lead
Regenerative option
2) Control circuit power supply lead
C
P+
L1
L2
L3
L11
L21
1) Main circuit power supply lead
Power supply
Servo amplifier
U
V
W
M
4) Servo motor power supply lead