148
4 STARTUP
4.6 Home position return mode
■
Method 7, 8, 11, 12: Homing on home switch and index pulse
These types include the operation at stroke end detection in addition to the operation of Method 3 to Method 6. Thus, the
home position is the same as that of Method 3 to Method 6. Method 7 has the operation of the dog type last Z-phase
reference home position return. Method 8 has the operation of the dog cradle type home position return at a forward rotation
start. Method 11 and 12 differ from Method 7 and Method 8 only in the starting direction: the starting direction of Method 11
and 12 is the reversed direction.
■
Method 17 to 30: Homing without index pulse
Method 17 to 30 have the operation of Method 1 to Method 14; however, these types set the home position not on the Z-
phase but on the dog. The following figure shows the operation of the home position return type of Method 19 and Method 20.
Method 19 and Method 20 have the operation of Method 3 and Method 4; however, these types set the home position not on
the Z-phase but on the dog Method 19 has the operation of the dog type front end reference home position return. Method 20
has the operation of the dog cradle type home position return; however, the stop position is not on the Z-phase but on the dog.
7
7
7
8
8
8
Index Pulse
Home Switch
Positive Limit Switch
19
20
19
Home Switch
20
Содержание MELSERVO-J4 series
Страница 2: ......
Страница 605: ...APPX Appendix 6 EC declaration of conformity 603 A ...
Страница 638: ...636 APPX Appendix 14 Encoder output pulse setting method MEMO ...
Страница 645: ......