APPX
Appendix 5 MR-J3-D05 Safety logic unit
601
A
Installation
Follow the instructions in this section and install MR-J3-D05 in the specified direction. Leave clearances between MR-J3-D05
and other equipment including the cabinet.
Combinations of cable/connector
MR-D05UDL_M (STO cable) for MR-J3 series cannot be used.
No.
Product
Model
Description
1)
Connector
MR-J3-D05
attachment
connector
Connector for CN9: 1-1871940-4
(TE Connectivity)
Connector for CN10: 1-1871940-8
(TE Connectivity)
2)
STO cable
MR-D05UDL3M-B
Cable length: 3 m
Connector set: 2069250-1
(TE Connectivity)
Cabinet
10 mm or
longer
80 mm or longer
for wiring
30 mm or
longer
10 mm or
longer
Top
Bottom
40 mm or
longer
40 mm or
longer
40 mm or
longer
30 mm or
longer
100 mm or longer
10 mm or
longer
Cabinet
Cabinet
MR-J3-D05
MR-J3-D05
MR-J3-D05
Other device
MR-J3-D05
attachment
connector
CN9
CN10
MR-J3-D05
2)
2)
CN8
MR-J4-_GF_(-RJ)
MR-J4-_GF_(-RJ)
1)
CN8