![Microchip Technology GridTime 3000 Скачать руководство пользователя страница 198](http://html1.mh-extra.com/html/microchip-technology/gridtime-3000/gridtime-3000_installation-manual_1786100198.webp)
This will make the new subscription settings appear.
3.
Enter Subscription's Destination IP Address
Enter the IP address of the SNMP client subscribing to GridTime 3000 notifications.
4.
Enter Subscription's User Name
When the SNMP version selected is SNMPv2, this field will be used as the security key. The key can consist of
any character combination, up to 32 characters maximum length.
If the SNMP version selected is SNMPv3, and the username of a user set up in the 'SNMP Users' window is
entered, then the user authentication settings will be applied. See
9.12.3. Provisioning SNMP Users
If SNMPv3 is being used and the username doesn't map to an SNMP user, SNMP notifications will be
unauthenticated and unencrypted.
Enter the user name for the SNMP subscriber.
5.
Select SNMP Version Used by Subscription
Select the SNMP version to be used by the SNMP subscriber from SNMPv1, SNMPv2c, and SNMPv3.
6.
Repeat Steps 2-5 for Each Additional Subscriber
Provisioning
©
2022 Microchip Technology Inc.
and its subsidiaries
Manual