2.
Follow the instructions in one of the following sections depending on your desired PTP Clock Mode:
–
9.5.7.2.1. End to End Default Profile Auto Mode
–
9.5.7.2.2. End to End Default Profile Server Only Mode
–
9.5.7.2.3. End to End Default Profile Client Only Mode
PTP Clock Mode Descriptions
Auto mode allows the port to operate either in the server or client state depending on whether the GridTime 3000 is
in sync or not. When the GridTime 3000 is in sync or in holdover, the port will be in the server or passive server state,
when the GridTime 3000 is out of sync the port will be in the client state.
In server only mode, the port will always either be in the server or passive server state depending on whether it has
won the BMCA .
In client only mode, the port will always be in the client or listening state depending on whether there is a PTP server
available to sync to.
9.5.7.2.1 End to End Default Profile Auto Mode
This section describes how to provision a PTP End to End Default Profile Auto Mode Clock.
1.
Select Auto for PTP Clock Mode
Select 'Auto' from the 'PTP CLOCK MODE' dropdown.
2.
Select Network Protocol
Select the network protocol PTP will operate on using the 'NETWORK PROTOCOL' dropdown.
The Network protocol should be consistent across the network subnet. The supported options are IPv4 (layer
4) and PTP over Ethernet (layer 2). By default the network protocol is set to IPv4 (UDP).
Provisioning
©
2022 Microchip Technology Inc.
and its subsidiaries
Manual
DS00004572A-page 104