6.
By default the 'ANNOUNCE RECEIPT TIMEOUT' is set to 3. This means that after 3 announce intervals, if
the device has not recieved an announce message it will trigger an announce receipt timeout event, which will
move the port into a listening state.
7.
Configure Server Networking Option
Select the 'SERVER NETWORKING OPTION' from either T1 or E1. The clock class rules will change to reflect
the selected option.
8.
Configure the Forced Quality
The 'SERVER FORCE QUALITY' option should be set to 'None' regardless of the Server Networking Option
selected.
9.
Add the PTP Peer
Click the blue 'ADD' button as shown. A tabbed collection of settings will be as displayed. Multiple peers can
be added, and will be accessible via the clicking the light blue tabs. Each will be numbered in the order they
were created. This is as shown below.
10.
Enable the Peer.
By default, the enable settings will be blank. Select 'ENABLE'. If desired, an operator can later disable the
peer without deleting it by selecting the 'Disable' option. A disabled peer will not send signaling messages, or
respond to sync messages.
11.
Configure the IP settings
Provisioning
©