Section 2 - Initial Setup and Calibration
Page 18
90-8M8022154 APRIL 2008
Setup Wizard Overview
Turning the key switch to the "RUN" position activates all VesselView units connected to
the system. Complete the initial setup process using the setup wizard when starting up any
VesselView unit for the first time, or after selecting "RESET SETTINGS" on the "FACTORY
RESET" screen. Menu path: "Main" > "Calibrate" > "Factory Reset". This process calibrates
each VesselView to the vessel's engine, sensor, and instrument configuration. The setup
wizard procedures include:
• Import configuration—This is used when a good configuration has been stored onto a
USB memory stick.
• Engine setup—This is used to define the size, type, and quantity of engines installed
on the vessel
• Display setup—This is used to define the screen configuration for your engines.
• Device setup—This is used to differentiate each VesselView Race Edition unit when
multiple VesselView's are installed on the vessel.
• Tank setup and calibration—This is used to define the tanks purpose, size, and location
on the vessel. Tanks will need to be calibrated so that the data displayed in VesselView
is accurate.
• Tab setup and calibration—This is used to define the number of tabs installed on the
vessel and their electrical connection. Tabs will need to be calibrated so that the data
displayed in VesselView is accurate.
NOTE: Trim is not part of the setup wizard but requires setup and calibration. Refer to
Section 4 - Trim Calibration
.
Repeat the setup wizard for each VesselView unit installed on the vessel. It is
recommended that the configuration setup and calibration settings be saved onto a USB
memory stick and imported onto other VesselView units rather than having to repeat the
setup procedure.
IMPORTANT: When VesselView Race Edition is first configured (during the setup wizard)
the system will automatically detect sensors that are present and ignores sensor inputs
that have no sensors attached. If a sensor is removed from the system after initial
configuration, VesselView will start to show faults for the removed sensor. To stop the fault
message perform the "Reset Sensor Detection" procedure. Refer to
Section 4 - Factory
Reset
. VesselView will rescan for sensors, and because the removed sensor no longer
exists, the fault message will go away.
Setup Wizard
The VesselView Race Edition setup wizard guides you through the first steps of configuring
VesselView. The setup wizard begins when the VesselView unit is turned on for the first
time or when a factory reset is performed. There are five areas that the setup wizard assists
in configuring; the engine, the display, the device, the tanks, and the tabs. The VesselView
setup wizard starts with the option to import a saved configuration from a USB memory
stick.
NOTE: A VesselView configuration needs to be previously exported (saved) to a USB
memory stick in order to perform the import function. Refer to
Section 4 - Save
Configuration
.
To skip the "IMPORT CONFIG" option, press the right arrow on the arrow trackpad. This
will continue the setup wizard and open the "ENGINE SETUP" screen (continue to the
Engine Setup
procedure in the setup wizard).
Содержание VesselView
Страница 7: ...Page iv 90 8M8022154 APRIL 2008...
Страница 54: ...Section 3 VesselView Race Edition Screen Overview Notes 90 8M8022154 APRIL 2008 Page 47...
Страница 137: ...Section 5 Propulsion Menu Notes Page 130 90 8M8022154 APRIL 2008...
Страница 145: ...Section 6 Vessel Menu Notes Page 138 90 8M8022154 APRIL 2008...
Страница 160: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 153...
Страница 166: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 159...
Страница 170: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 163...
Страница 178: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 171...
Страница 183: ...Section 8 Installation and Wiring Notes Page 176 90 8M8022154 APRIL 2008...
Страница 185: ...Section 8 Installation and Wiring Notes Page 178 90 8M8022154 APRIL 2008...