Section 2 - Initial Setup and Calibration
Page 32
90-8M8022154 APRIL 2008
iv. Press the left or right arrow on the arrow trackpad to change the "ACTUAL" to
read the same as the "CURRENT ACTUAL %".
32805
IMPORTANT: It is not necessary to perform the procedure using quarters of a tank,
although this will establish a more accurate tank calibration. It is most important that, at
minimum, empty (0%) and full (100%) are calibrated. VesselView will calculate the quarter
percentages using the empty and full data.
v. Begin filling the tank in 25% intervals.
vi. Press the down or up arrow on the arrow trackpad and highlight the interval
"25%, 50%, 75%, or 100%" field.
vii.Press the left or right arrow on the arrow trackpad to change the "ACTUAL" to
read the same as the "CURRENT ACTUAL %".
32806
viii.Press the check button to confirm your changes for that tank.
Содержание VesselView
Страница 7: ...Page iv 90 8M8022154 APRIL 2008...
Страница 54: ...Section 3 VesselView Race Edition Screen Overview Notes 90 8M8022154 APRIL 2008 Page 47...
Страница 137: ...Section 5 Propulsion Menu Notes Page 130 90 8M8022154 APRIL 2008...
Страница 145: ...Section 6 Vessel Menu Notes Page 138 90 8M8022154 APRIL 2008...
Страница 160: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 153...
Страница 166: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 159...
Страница 170: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 163...
Страница 178: ...Section 8 Installation and Wiring Notes 90 8M8022154 APRIL 2008 Page 171...
Страница 183: ...Section 8 Installation and Wiring Notes Page 176 90 8M8022154 APRIL 2008...
Страница 185: ...Section 8 Installation and Wiring Notes Page 178 90 8M8022154 APRIL 2008...