Roundbaler DIAVEL 630
– DIAVEL 630 CUT
USE AND MAINTENANCE MANUAL
- 60 -
Too low RPM
Increase the rpm PTO of the baler
Irregular net distribution on the
bale surface
The net is not stretched between
the support and the binder
Check the net brake
Check the condition of the wear of
the net brake, adjust the roller
brake action on the eyelet of the
tension spring.
Net is not correctly dragged into
the pressing chamber from the
material
The net get too much braked
Reduce the force of the net brake.
The net ends up on the rotor
Net braking not sufficient
Increase the force of the net
brake.
The ligature doesn’t work
automatically.
Net/Twine Sensors otut of
position
Adjust the distance from the
sensor (Par. 6.5.1), if persists,
change the sensor.
Product is not cut correctly
Cutting knives not activated
Actuate cutting knives
Knives not sharp
Remove and sharpen knives
Net is not cut correctly
Incorrect positioning of the brake
coil
Bring the brake coil in contact with
the coil
Wrong adjustment of the net
brake
Adjust the roller brake net acting
on the eyelet of the tension spring
Cutting blade worn out
Replace the cutting blade
Twine not cut correctly
Cutting blade worn out
Replace the cutting blade
Irregular twine ligature
Twine not brake.
Increase the force of the twine
brake
Twine ligature only in the middel
The trolleys don’t catch the twine
Decrease the winding diameter of
the driving pulley
The twine is not dragged by the
bale
Incorrect way of strings
Check the way of strings (par.
5.4.8)
Twine braked excessively
Reduce the braking force of the
string
Presence of knots or tangles in
the string or in the coil
Check and remove any knots or
tangles of the string
The terminal doesn’t switch on
No power supply
Check the 2A fuse located near
the control unit
The electro valves and the motors
don’t work.
No power supply for electro
valves/motors
Check the 30A fuse located in the
close to the control unit
The terminal cannot detect the net
cutting.
Malfunction of the sensor net Cut
Adjust the sensor distance (par.
6.4.1), if the problem persists,
replace the sensor
The terminal signals the door
open alarm even with closed door
Malfunction of the rear door
sensor
Adjust the sensor distance (par.
6.4.1), if the problem persists,
replace the sensor
The terminal does not detect the
pressure of the bale
Malfunction of the pressure switch
P1 e P2
Replace the pressure switch P1 e
P2
The terminal detects the bottom
floor always open
Malfunction of the drop bottom
floor sensor
Adjust the distance from the
sensor (Section 6.4.1), if the
problem persists, replace the
sensor
The terminal does not detect the
activation of the cut
Malfunction of the knives sensors
Adjust the sensor distance (par.
6.4.1), if the problem persists,
replace sensors
Содержание Diavel 630
Страница 1: ...Prima di iniziare ad operare con la macchina leggere le istruzioni per l uso...
Страница 17: ...Roundbaler DIAVEL 630 DIAVEL 630 CUT USE AND MAINTENANCE MANUAL 17 Fig 4 Safety signs...
Страница 69: ...Roundbaler DIAVEL 630 DIAVEL 630 CUT USE AND MAINTENANCE MANUAL 69...
Страница 70: ...Roundbaler DIAVEL 630 DIAVEL 630 CUT USE AND MAINTENANCE MANUAL 70...
Страница 71: ......