ABSOLUTA Plus
PROGRAMMING FROM THE PC
75
EVENTS
OCCURS WHEN...
ENDS WHEN...
Warning Power
Trouble on
Power Station
... the Battery of a Power Supply Station fails
the Dynamic test or it is disconnected, or the
Power Supply Station polarity inversion fuse
blows.
... the Batteries of ALL the Power Supply Sta-
tions are connected and pass the Dynamic test
and ALL the Power Supply Station polarity in-
version fuses are replaced.
Battery not
Connected on
Power Station
... the voltage of a Power station battery is be-
low 10.2 V at power up (the battery is ex-
hausted).
... the voltage of ALL the Power station batter-
ies rises above 12 V.
Battery Charger
Trouble on
Power Station
... the output voltage of a Power station power
supply module is 0.5 V above or below the pre-
set value.
... the output voltage of ALL the Power station
power supply modules is 0.5 V above or below
the preset value.
Short Circuit
Output 1/2/3 on
Power Station
... the current draw of a Power station output is
over 1.8 A.
... the current draw of ALL the Power station
outputs is over 1.8 A.
Battery Charger
Disconnected on
Power Station
... the output voltage of a Power station power
supply module is 0.5 V above the preset value.
... the output voltage of ALL the Power station
power supply modules is 0.5 V below or equal
to the preset value.
Reset on Panel
...
Alarms Reset
is requested.
SPOT EVENT!
Chime on Panel
... a Zone with the
Chime
Attribute detects
Alarm conditions when its Partition is Dis-
armed.
SPOT EVENT!
Negligence on
Panel
... the
Negligence Time
expires.
SPOT EVENT!
Delinquency on
Panel
... the
Inactivity Time
expires.
SPOT EVENT!
Test
... programmed (see
System Options
>
Time
>
Periodic Test Transmission
).
SPOT EVENT!
Installer
Maintenance
... programmed (see
System Options
>
Time
>
Installer Maintenance
).
SPOT EVENT!
Balanced
Tamper
...
Balanced Tamper
is set for the
Panel AS
Tamper
option AND the
AS
terminal is unbal-
anced.
...
Balanced Tamper
is set for the
Panel AS
Tamper
option AND the
AS
terminal is bal-
anced (grounded with a 10,000 ohm resistor).
Tamper on Main
Unit (Seized)
... the Control Panel wall-tamper switch opens.
...the Wall-Tamper switch restores.
Loss of
Wireless
Detectors
... one of the
Loss of Wireless Detector
events
occurs (see Table 11 on page 72).
... ALL the
Loss of Wireless Detector
events end
(see the Table 11 on page 72).
Zone Alarm on
Panel
... a zone detects Alarm conditions.
... ALL zones restore to standby status
Zone Tamper on
Panel
... a zone detects Tamper conditions.
... ALL Tamper conditions are no longer pres-
ent on the zones.
Real Time Zone
on Panel
... the voltage (resistance) on a Zone enters the
Alarm Range
... voltage (resistance) on ALL Zones restore to
Standby Range.
Zone Bypass on
Panel
... a Zone is bypassed.
... ALL Zones is restored.
Partition Alarm
on Panel
... a Partition goes into Alarm Status.
... ALL Partition restore to Standby Status.
Partition Tamper
on Panel
... a Partition goes into Tamper Status.
... ALL Partition restore to Standby Status.
Partial Arming
on Panel
... a Partition Arms in Stay Mode or in Stay
mode with Zero Delay.
... ALL Partitions Arm in Away Mode or Disarm.
Global Arming
on Panel
... a Partition Arms in Away Mode.
... ALL Partitions Arm in Stay Mode or Stay
mode with zero delay or Disarm.
Exit Time on Panel
... a Partition Arms in Stay or Away Mode.
... ALL Partition
Exit Dealy
expire.
Entry Time on
Panel
... a Entry Delay Zone goes into Alarm Status
when its Partition is Armed in Stay or Away
Mode.
... ALL Partition
Entry Delay
expire or ALL Par-
titions Disarm.
Table 14
System Events (continued on next page).