e
In order to comply with the EN50136-2 and
EN50136-1 standards, the option
Periodic Test
Transmission
should ENABLED and the
Periodic
Test Transmission interval
MUST NOT be more
then 1,500 minutes (25 hours) for Grade 2 Control
Panels (ATS classification: SP2 or DP1) and 90 s
for Grade 3 Control Panels (ATS classification:
SP5 or DP4).
Installer Maintenance Time
Set the date and the time
of the first
Installer Maintenance
event.
Installer Maintenance Interval
Set the time that must
elapse between a
Installer Maintenance
event and the
next.
Valid entries:
0 through 65,535 minutes.
Surveillance Maintenance Time
Set the date and the
time of the first
Surveillance Maintenance on Panel
event.
Surveillance Maintenance interval
Set the time that
must elapse between a
Surveillance Maintenance on
Panel
event and the next.
Valid entries:
0 through 65,535 minutes.
Daylight saving time/Daylight saving time - restored
If required, change the date and hour for Summer time
begins/ends:
Ø
the Panel moves
1 hour forward
its clock, on date
and time set for the
Daylight saving time
options;
Ø
the Panel moves
1 hour back
its clock, on date and time
set for the
Daylight saving time - restored
options;
The system will signal Automatic Changeover by:
Ø
switching ON the
G
LED.
+
The
G
LED signals several different types of Trouble
events. If signalling is due to the Standard time/Sum-
mer time changeover, the Keypad (in View Trouble
Mode) will show the
summer time
message.
Default:
the Panel moves its clock 1 hour forward at 2
AM of the last March’s Sunday and 1 hour back at 3 AM
of the last October’s Sunday, until 2030.
n
Received Call
Number of Rings
Set the number of rings the Control
panel must allow before answering an incoming call.
+
If the
Double call
option is enabled, the
Number of
Rings
will be ignored (refer to “Double call” below).
Double Call Enable
This option will allow the Control
Panel to share the telephone line with another answer-
ing device (answering machine, fax, etc.). Under nor-
mal circumstances, the device which allows the least
number of rings will answer any incoming calls. How-
ever, if this option is Enabled, the Control panel will
override the other answering device when it recognizes
the Double Call sequence.
Double Call sequence:
the caller must allow at least 2
rings but not more than the rings set for the other an-
swering device, hang up, wait for a few seconds and
callback within 60 seconds. The Control panel will an-
swer on the first ring of the second call.
+
The other answering device must be programmed
to answer after 3 or more rings.
n
Phone Options
Call Confirmation
If this option is
enabled
, the Con-
trol Panel will not consider a call successful until the call
receiver presses the star key on the telephone keypad,
in order to generate a feedback signal.
Default:
Enabled.
+
If this option is enabled, you should include a re-
quest for the feed back signal (press star) in the
message.
Call attempts
Set the maximum number of Call at-
tempts for each Telephone Number.
You have the following preset, unmodifiable, delays be-
tween call attempts:
Ø
approx. 10 s between attempts to digital numbers;
Ø
approx. 25 s between attempts to different vocal numbers;
Ø
approx. 75 s between attempts to the same vocal number.
Valid entries:
1 to 99.
Default:
4.
e
In order to comply with the EN50136-2 standard,
the
Call attempts
option MUST NOT be less then
2 and more then 4.
Voice in line
If this option is ENABLED, the Voice
message will be played after detection of a voice re-
sponse. If the Control Panel does not detect a voice re-
sponse before the
Wait voice timeout
ends, it will
hang-up and generate a
Dialler action failed
event.
Default:
Enabled.
Wait voice timeout
Set the pause after dialling. If the
Control Panel does not detect a voice answer before
the
Wait voice timeout
ends, it will hang-up and gener-
ate a
Dialler action failed
event.
+
The
Wait voice timeout
applies to the
Voice on
Line
option.
Valid entries:
0 through 240 seconds, in 1 second steps.
Default:
30 seconds.
Transmission Delay Enabled
If
this
option
is
ENABLED, the Voice message will be played when the
programmed
Wait after select
expires.
If both
Voice in line
and
Transmission Delay
options
are DISABLED, the Voice message will be played after
dialling.
+
All calls that comply with the programmed
Send
Message After
conditions will be considered Suc-
cessful. However, only the
Voice in Line
option
ensures a proper response to calls, therefore, if
you disable this option or enable the
Transmis-
sion Delay
option, you should also enable
Call
Confirmation
option.
ABSOLUTA Plus