A Arming Label
Enter the message that the Keypads
should show when Type
A
Arming takes place, as
shown in Figure 28 (
1
) for the Touch keypad.
Valid entries:
up to 16 characters.
Default:
STAY type A.
B Arming Label
Enter the message that the Keypads
should show when Type
B
Arming takes place, as
shown in Figure 28 (
2
) for the Touch keypad.
Valid entries:
up to 16 characters.
Default:
STAY type B.
C Arming Label
Enter the message that the Keypads
should show when Type
C
Arming takes place, as
shown in Figure 28 (
3
) for the Touch keypad.
Valid entries:
up to 16 characters.
Default:
STAY type C.
D Arming Label
Enter the message that the Keypads
should show when Type
D
Arming takes place, as
shown in Figure 28 (
4
) for the Touch keypad.
Valid entries:
up to 16 characters.
Default:
STAY type D.
LCD Keypad Standby Page
Enter the message that
the LCD Keypads should show in standby status.
Valid entries:
up to 16 characters.
Default:
BENTEL ABSOLUTA.
A Arming Description
Insert a text that describes
arming Type
A
: this text will be shown in the Touch Key-
pad when the corresponding arming is selected, as
shown in Figure 28 (
6
).
Valid entries:
up to 128 characters.
Default:
empty.
B Arming Description
Like “A Arming Description”
but for arming type B.
Valid entries:
up to 128 characters.
Default:
empty.
C Arming Description
Like “A Arming Description”
but for arming type C.
Valid entries:
up to 128 characters.
Default:
empty.
D Arming Description
Like “A Arming Description”
but for arming type D.
Valid entries:
up to 128 characters.
Default:
empty.
Global Arming Description
Like “A Arming Descrip-
tion” but for Global arming.
Valid entries:
up to 128 characters.
Default:
empty.
Squawk Time On
Set squawk (short audible signal)
duration to signal confirmation of arming/disarming or
arming locking (see “USER MANUAL > APPENDIX >
Arming block conditions”), implemented via the com-
mand zone or keyfob:
Ø
one
squawk confirms arming/disarming
Ø
two
squawks indicate that arming was refused
Squawk Time Off
Set the pause between the two
squawks of inhibited arming signalling.
Main Board Wired Siren Squawk
This menu shows
the label assigned to output no. 1 (see
Outputs
options
group): select the label of output no. 1 to enable
squawk.
Default:
Disabled.
+
The options
Squawk Time On
,
Squawk Time Off
,
and
Main Board Wired Siren Squawk
, apply only to
the sirens connected to output no. 1 (terminals
NC
,
COM
,
NO
,
+N
,
+A
).
Bypass tampers and faults on Zone
If enabled, by-
passed zones CANNOT trigger
Tamper On Zone
events and
System
>
Zone Fault/Masking
.
Enable Auto Arming
If this option is enabled the Con-
trol Panel can perform the auto arming set in the
Arm-
ing Schedule
option group.
Mains Fault Timeout
This option will allow you to set
the amount of time that must expire before the
Warning
mains failure
event occurs.
Valid entries:
0 through 250 minutes, in 1-minute steps
Default:
0 minutes.
e
In order to comply with the EN50131-1, EN50131
and EN50131-3-6 standards, this option should not
be more than 1 minute.
Panel Identifier Code
Enter the ID Code assigned to
the control Panel during the Wizard Setup.
+
The Panel ID Code set in BOSS must match with
the one set during the Wizard Setup of the Control
Panel to Downloading/Uploading by means an
USB key.
60
Expandable Hybrid Control Panel
Figure 28
Arming by the Touch Keypad: labels
1
,
2
,
3
and
4
can be customised, as explained in the text; the
corresponding Special arming initial letter will be put in
position
5
; the description assigned to the arming se-
lected will appear in window
6
, as explained in the text.