n
Caller ID over GSM events
These events (Table 17) occur when the GSM Module
receives a call from the respective telephone number,
as long as the
Caller ID over GSM
option for the tele-
phone number is ENABLED (see the
Phonebook
op-
tion group).
When the control panel receives the call from the tele-
phone number, it hang up after a few rings and per-
forms the programmed actions: then the control panel
confirms this by ringing the telephone number, if the
Ringback Enabled
option is ENABLED.
+
The ringback for confirmation may be delayed if there
are other calls in the queue or may be lost if the queue
is full or because of problems on the GSM network.
Ringback Enabled
If disabled (default), the event will
NOT ring back for confirmation.
If ENABLED, the event will ring back for confirmation.
n
Default settings
The default settings for the
Events and Actions
Option
Group are made to provide a control panel that can be
immediately operative with a minimum setup, as indi-
cated on Table 10: the events listed on the
EVENTS
col-
umn, activate the Outputs shown on the
FIRST OUTPUT
column and send the Vocal Messages composed by the
Messages shown on the
MESSAGE VIA TELEPHONE
,
to ALL
Voice Dialer
numbers in the Phonebook.
e
In order to comply with the EN50131-1 and
EN50131-3
standards, the
First Output
,
Third
Message
and
Telephone Enabled
, about events
on the Table 10, should NOT be modified, only the
Telephone Enabled
option relevant to the
Gen-
eral System Tamper
event can be modified.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
71
EVENTS
STATUS
FI
RST
O
UTPUT
MESSAGE VIA TELEPHONE
Telephone
Enabled
FIRST
M
ESS.
SECOND MESSAGE
THIRD MESSAGE
Zone Alarm (Hold-up)
ON
— 1
2 (Alarm)
14 (Hold Up in progress)
Yes
OFF
5 (Alarm Restoral)
General System Alarm
ON
1
1
2 (Alarm)
—
Yes
OFF
5 (Alarm Restoral)
General System Tamper
ON
2
1
3 (Tamper)
—
Yes
OFF
6 (Tamper Restoral)
Low Battery on Wireless
Detectors
ON
— 1
4 (Fault)
12 (Wireless Batteries)
Yes
OFF
7 (Fault Restoral)
Warning Mains Failure
ON
— 1
4 (Fault)
10 (Main AC)
Yes
OFF
7 (Fault Restoral)
Warning Low Battery
ON
— 1
4 (Fault)
11 (Panel Battery)
Yes
OFF
7 (Fault Restoral)
Battery Power Trouble
ON
— 1
4 (Fault)
11 (Panel Battery)
Yes
OFF
7 (Fault Restoral)
System Fault
ON
3 —
—
—
No
OFF
Automatic Arming Refused
ON
— 1
8 (General Activation)
13 (Auto arming failed)
Yes
OFF
9 (Restore General Activation)
Tamper on Armed System
ON
1
1
3 (Tamper)
—
Yes
OFF
6 (Tamper Restoral)
Table 10
Default settings for the
Events and Actions
Option Group: Output nr. 1 is assigned to terminals
NC
,
COM
,
NO
,
+A
and
+N
on the Main Board; Outputs nr. 2 and 3 are, respectively, assigned to terminals
O1
and
O2
on the Main
Board.