1.9) Option Programming by Keypad
To set the main control panel options using a keypad,
complete the following steps.
1.
Access the Installer menu, as indicated in the para-
graph “Access to the operations”.
INSTALLER
1act. 2prg 3view
2.
Select the
Action
option by pressing
1
.
INSTALLER
1.1
ZONE test
3.
Select
Panel Prog.
INSTALLER
1.9
Panel Prog.
4.
Press
ENTER
.
Panel Prog.
Zones
Zn---
5.
Select the Option Group you want set up by press-
ing
a
and
b
then press
ENTER
and refer to the rela-
tive paragraph.
+
The Installer Menu Timeout is suspended during
the Option Programming. The keypad exits from
the Installer Menu when you press
ESC
after the
Installer Menu Timeout has expired.
n
Zones
Panel Prog.
Zones
Zn---
The
Zone
option let you to set up the Zone Partitions as
follow.
1.
Enter the Identification Number of the Zone you
want set up.
Zone
001
Zones
Zn001
2.
Press
ENTER
.
Zones
Zn001
Part mask
3.
Press
ENTER
again: the characters on the display
bottom line show the Partitions of the selected
zone: the 1st is for Partition 1, the 2nd is for Partition
2 and so on, as follow.
Ø
*
: the Zone is assigned to the Partition.
Ø
-
: the Zone is NOT assigned to the Partition.
Part mask
Zn001
*---------------
4.
Set up the Zone Partitions as follow.
Ø
Press
a
to assign ALL the Partitions to the Zone.
Ø
Press
b
to assign none Partition to the zone.
Ø
Press
c
and
d
to scroll the Partitions: a blinking char-
acter indicates the currently selected Partition.
Ø
Press
ON
to assign the selected Partition to the
Zone.
Ø
Press
OFF
to NOT assign the selected Partition to
the Zone.
Ø
Press
ENTER
to confirm the Zone Partitions or
ESC
to discharge the changes, and go back to step
1
.
Part mask
Zn001
*--------------*
In the top example, Zone 1 is assigned to the Partitions
1 and 16.
n
Partition
Panel Prog.
Partition
Pt---
The
Partition
option let you to set up the Entry and Exit
Times for the Partitions, as follow.Enter the Identifica-
tion Number of the Zone you want set up.
1.
Enter the Identification Number of the Partition you
want set up.
Partition
01
Partition
Pt001
2.
Press
ENTER
.
Partition
Pt001
Entry time
3.
Press
a
and
b
to scroll the
Entry time
and
Exit
time
, then press
ENTER
to select the displayed op-
tion: the display bottom line shows the current value
on the left, and the valid range on the right.
Entry time Pt001
30s :
15/3600
4.
Enter the required value.
Ø
You must enter a 4-digit value: e.g. you must press 0,
0, 6 and 0 to enter 60 seconds.
Ø
Press
ESC
to delete the value.
Ø
Press
ESC
again to to discharge the changes and go
back to step
3
.
Ø
Press
ENTER
to confirm the value and go back to
step
3
.
108