ABSOLUTA Plus
APPENDIX
129
Option
Description
Detection
Sensitivity
This option sets the detector's PIR sensitivity.
If you select
One Region
the detector goes into alarm when you cross just one detection
zone.
If you select a value different from
One Region
the detector goes into alarm when you cross at
least two detection zones.
Optional settings:
Low
,
Medium
(default),
High
, or
One Region
.
Disarm Activity
This option sets the time that the detector continues to detect motion, after disarming control
panel.
If you select
Not Active
, the detector does not detect motion after disarming control panel.
If you select a value different from
Not Active
, the detector continues to detect motion after
control panel disarming, for the delay indicated in the value.
Optional settings:
Not Active
(default),
Yes - No Delay
,
Yes - 5 Second Delay
,
Yes - 15 Second De-
lay
,
Yes - 30 Second Delay
,
Yes - 1 Minute Delay
,
Yes - 5 Minute Delay
,
Yes - 10 Minute Delay
,
Yes
- 20 Minute Delay
, or
Yes - 60 Minute Delay
.
Event Counter
This option sets the number of motions that the detector must detect to go into alarm.
If you select
Low Sensitivity
the detector goes into alarm when detects at least two motions.
If you select
High Sensitivity
the detector goes into alarm when detects just one motion.
Optional settings:
Low Sensitivity
(default), or
High Sensitivity
.
Exit Entry Beeps
If you enable this option, the siren sounds beeps and activates the light signal, when exit de-
lay and entry delay are active.
+
The light signal is ON steady, and activates also when option
Strobe
is disabled.
Optional settings:
Disabled
(default), or
Enabled
.
External Input 1
If you enable this option, you can associate the external input 1 of the device to a logical zone
of the control panel.
Optional settings: disabled (BW-IO default), or enabled (BW-312, BW-MCN, and BW-SHK
default).
External Input 1
End of Line
This option sets the standby status, and end of line type, of external input 1 of the device.
For wiring instructions of the external input, refer to the device's instructions.
Optional settings:
End of Line
(default),
Normally Open
,
Normally Closed
, or
Double End Of
Line
.
External Input 2
If you enable this option, you can associate the external input 2 of the device to a logical zone
of the control panel.
Optional settings: disabled (default), or enabled.
External Input 2
End of Line
Similar to
External Input 1 End of Line
but for external input 2 of the device.
External Input 3
If you enable this option, you can associate the external input 3 of the device to a logical zone
of the control panel.
Optional settings: disabled (default), or enabled.
External Input 3
End of Line
Similar to
External Input 1 End of Line
but for external input 3 of the device.
External Input 4
If you enable this option, you can associate the external input 4 of the device to a logical zone
of the control panel.
Optional settings: disabled (default), or enabled.
External Input 4
End of Line
Similar to
External Input 1 End of Line
but for external input 4 of the device.
Freezer: Threshold
This option sets the threshold for the freezer temperature alert. Event
Temperature Above
Freezer Threshold on Zone
occurs when the temperature measured by the device remains
above the temperature set in this option, for the time set in
Freezer: Wait before alert
option.
The event restores when the temperature measured by the device remains at least 1°C be-
low the temperature set in this option, for the time set in
Freezer: Wait before restore
option.
Optional settings: from -29°C to 39°C (default -10°C)
Table 24
Wireless device options.