Wireless device options
Table 24 describes the wireless device options. For fur-
ther information, refer to the devices’ instructions.
128
Expandable Hybrid Control Panel
Option
Description
Activity LED
If you enable this option, the activity LED of the device flashes to indicate that the device is
operating.
If you disable this option, the activity LED is off.
Optional settings: disabled (default), or enabled.
Alarm Direction
This option sets the detection direction. The right and left directions refer to the point of view
of the installer while observing the detector in its mounting position.
Optional settings:
Left to right
,
Right to left
, or
Both
(default).
Alarm Hours
This option sets the detector to report alarm always, or only when it is dark.
Optional settings:
Day and Night
(default), or
Night only
.
Alarm LED
If you enable this option, the alarm LED of the device signals the motion detection.
If you disable this option, the alarm LED is off.
Optional settings: disabled, or enabled (default).
Anti-Masking
If you enable this option, the control panel reports a fault when the microwave sensor is
masked:
Ø
event
Zone Fault/Masking
, relative to the detector's zone, occurs
Ø
the keypad signals the
Fail detect. nn
fault, where nn is the detector number
Ø
the even logger memorizes the
Masked Zones
event, and the zone label
Optional settings: disabled, or enabled (default).
Anti-Masking PIR
This option sets the sensitivity level of infrared sensor anti-masking.
If you select
Low Sensitivity
or
High Sensitivity
, the control panel reports a fault when the de-
tector's infrared sensor is masked:
Ø
event
Zone Fault/Masking
, relative to the detector's zone, occurs
Ø
the keypad signals the
Fail detect. nn
fault, where nn is the detector number
Ø
the even logger memorizes the
Masked Zones
event, and the zone label
Optional settings:
Disabled
,
Low Sensitivity
(default), or
High Sensitivity
.
Auto Tamper
Alarm
If you enable this option, the siren sounds a continue tone when it cannot communicate with
the control panel, and when it is open, or removed from the mounting surface.
Optional settings: disabled (default), or enabled.
Cold: Threshold
This option sets the threshold for the cold temperature alert. Event
Temperature Below Cold
Threshold on Zone
occurs when the temperature measured by the device remains below the
temperature set in this option, for the time set in
Cold: Wait before alert
option. The event re-
stores when the temperature measured by the device remains at least 1°C above the
temperature set in this option, for the time set in
Cold: Wait before restore
option.
Optional settings: from -29°C to 39°C (default 19°C)
Cold: Wait before
alert
This option sets the time that the temperature measured by the device must be below the
temperature set in the
Cold: Threshold
option, before
Temperature Below Cold Threshold on
Zone
event occurs.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Cold: Wait before
restore
This option sets the time that the temperature measured by the device must be at least 1°C
above the temperature set in the
Cold: Threshold
option, before
Temperature Below Cold
Threshold on Zone
event ends.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Detection Range
This option sets the detection range of the detector:
Ø
Minimum
= 2 m for BW-IRT, 3 m for BW-902
Ø
Medium
= 4 m for BW-IRT, 5 m for BW-902
Ø
Maximum
= 6 m for BW-IRT, 8 m for BW-902
Optional settings:
Minimum
,
Medium
, or
Maximum
(default).
Table 24