Type
This option allow you to program the Output
standby status.
r
Normally Open
— In the standby status the Open
Collector Outputs
6
are open.
r
Normally Closed
— The electrical state during
standby is: Positive (13.8 V) on the [+N] terminal [+A]
terminal open; [COM] terminal closed to terminal
[NC]; [NO] terminal open; the Open Collector Out-
puts are closed to Negative.
+
The Relay Output can be programmed as Normally
Closed ONLY.
Reserved
This option will allow the User to acti-
vate/deactivate the Output from the Keypad and via
telephone
(refer
to
“Outputs
(ON/OFF)”
under
“OPERATING YOUR SYSTEM FROM A KEYPAD”
section and “Turn Reserved Outputs ON/OFF” under
“OPERATING THE SYSTEM FROM A TELEPHONE"
section in the USER MANUAL).
+
The user may activate or deactivate ONLY the Re-
served Outputs that share at least one Area with
the PIN and the keypad used (the telephone is en-
abled over all Areas): see the
Partitions
option.
+
The Master PIN can activate/deactivate the Out-
put, via Status page, if the output is programmed
as
Reserved
. If the output is not
Reserved
, only
the Installer can activate/deactivate it.
+
Reserved
Outputs CANNOT be associated with
the Events on the Events-Actions page.
When you exit a programming session via PC or Key-
pad, the Reserved Outputs will restore to the status
they were in before the programming session started.
Monostable-Enabled
If this option is disabled (at de-
fault) the Output is Bistable: it will activate when AT
LEAST ONE of its associated Events occurs, and will
stop when ALL of its associated Events end.
If this option is enabled, the Output is Monostable: it will
activate when AT LEAST ONE of its associated Events
occurs, and will stop when the programmed
ON Time
expires (see “ON Time” below).
+
You cannot enable the
Monostable
option for
wireless sirens.
Monostable-Time ON
This is the maximum activation
time of the Output.
Valid entries:
1 through 25 seconds, in 1-second
steps; 1 through 127 minutes, in 1-minute steps.
Default:
3 minutes.
Monostable-Time OFF
This is the minimum OFF
Time after restoral of the Output. The Output will be un-
able to re-activate until the programmed OFF Time ex-
pires.
Valid entries:
1 through 255 seconds, in 1-second
steps;
Default:
6 seconds.
+
The
Monostable-Time On
and
Monostable-Time
Off
can be set for Monostable Outputs ONLY.
Timer
This option will allow you to associate a Timer
with the Output. The Output can be activated ONLY
when the selected Timer is in the active state (refer to
“Timer”).
+
When the Timer window expires, the Output will re-
store to standby, even if the conditions that gener-
ated the event are still present.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
57
... occurs
... ends
EVENT
... active
... standby
Bistable
OUTPUT
... active
... standby
Monostable
OUTPUT
Half cycle
ON time
OFF time
1 Cycle
st
2 Cycle
nd
the event ends here
Figure 27
The Effect of the
Half cycle
and
Cycle
options on Bistable and Monostable Outputs
6
The Open Collector Outputs are: the terminals O1 and O2 on the Main Board; the terminal T1, T2, T3 or T4 on the
Main Board, when set as Output; the Terminal T1, T2, T3, T4, T5 or T6 on the Input/Output Expander, when set as
output.
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...
Страница 98: ...98 Expandable Hybrid Control Panel...