3.2) View the Firmware Version
You can view the version of the Control Panel Firmware
as follow.
1.
Access the Installer menu or the Level 4 menu, as
indicated in the paragraph “Access to the opera-
tions”.
INSTALLER
1act. 2prg 3view
2.
Select the
View
option by pressing
3
.
INSTALLER
3.1
View LOG
3.
Select
Firmware Version
.
INSTALLER
3.2
Firmware version
4.
Press
ENTER
.
ABS
FW 4.00.19
Z=128 sn12345678
The display shows the following information.
Ø
ABS FW 4.00.19
: the firmware version.
Ø
Z=128
: the ABS-128 main board model.
Ø
Z=048
: the ABS-48 main board model.
Ø
Z=018
: the ABS-18 main board model.
Ø
sn12345678
: the Serial Number.
5.
Press
c
or
d
to view the firmware versions of the
GSM module, the IP module, and the transceiver:
GSM FW 02.01.07
IP FW 01.00.00
PGH HOST 1.00.26
PGH MODEM
2.035
+
The display shows only firmware versions of the in-
stalled modules.
+
The firmware versions and serial number dis-
played may differ from those shown in the exam-
ples above.
3.3) View Zone Status and Zone Bypassing
You can view the zone status (standby, alarm, tamper,
short-circuit, bypassed, included) and bypass the
zones as follow.
1.
Access the Installer menu, as indicated in the para-
graph “Access to the operations”.
INSTALLER
1act. 2prg 3view
2.
Select the
View
option by pressing
3
.
INSTALLER
3.1
View LOG
3.
Select
Zone status
.
INSTALLER
3.3
Zone status
4.
Press
ENTER
.
Zone status
---
5.
Select the required zone by entering its ID number
or scrolling by pressing
a
and
b
: the display bottom
line shows the label of the selected zone.
Zone status
001
Zone
001
6.
Press
ENTER
: the display bottom line shows the
zone status as follow.
Ø
ST_BY
: the zone is in standby.
Ø
ACTIVE
: the zone is active.
Ø
OPEN
: the zone is open (tampered).
Ø
SHORT
: the zone is short-circuited.
Ø
FAULT
: the zone is faulty (ONLY Grade 3 Control
Panels)
Ø
WORKING
: the zone is operative (included).
Ø
BY-PASS
: the zone is bypassed.
Zone
001
ST-BY
WORKING
7.
Press:
Ø
OFF
to bypass the zone,
Zone
001
Bypassed now
then press
ESC
to go back to step
5
;
Ø
ON
to include the zone,
Zone
001
Included
then press
ESC
to go back to step
5
;
ABSOLUTA Plus
KEYPAD OPERATIONS
117
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...