this information.
Default:
8.8.8.8 (google).
+
This option is locked if the
Obtain an IP address
automatically
option is enabled.
Ethernet speed configuration
Select the Ethernet in-
terface speed for the IP Module.
Ø
Automatic
(default);
Ø
10 Mbps, Half Duplex
;
Ø
100 Mbps, Half Duplex
;
Ø
10 Mbps, Full Duplex
;
Ø
100 Mbps, Full Duplex
.
DNIS
Enter the DNIS number (Dialed Number Identifi-
cation Service), if required.
Default:
none.
Fibro Account #
Enter the Customer Code for the
Fibro
20
protocol: ask the Central Station.
Default:
0000FFFFFF.
+
Ensure a different Customer Code is assigned to
each Control Panel that transmits events to the
same receiver.
Receiver Functionality Mode
Select the operating
mode of the receivers:
Ø
Primary and Backup
(default), the Backup Receiver
will only be used when communication fails on the
Main receiver;
Ø
Redundant
, events will be sent to the Main and
Backup Receiver at the same time.
+
If you intend to use only one receiver, the primary
receiver options must be programmed.
Account #
Enter the Customer Code for the Contact
ID and SIA protocols: ask the Central Station.
Default:
0000.
Communication Protocol
Select the protocol speci-
fied by the Central Station:
Ø
SIA over FIBRO
;
Ø
Contact ID over FIBRO
.
Default:
Contact ID over FIBRO.
SIA Code for Panel Lost Event
Enter the SIA Event
code that must be sent when the IP module cannot
communicate with the Control Panel.
Default:
00.
CID Code for Panel Lost Event
Enter the Contact ID
Event code that must be sent when the IP module can-
not communicate with the Control Panel.
Default:
000.
Encryption Enabled
If enabled, communication with
the receiver will be encrypted with a variable key.
Default:
enabled.
3
In order to comply with EN50131 Grade 3 stan-
dards, the option must be enabled.
Receiver 1 IP Address (Receiver 2 IP Address)
En-
ter the IP address of the Main (Backup) receiver pro-
vided by the Central Station.
Default:
0.0.0.0.
+
The
Receiver 2 IP Address
option is locked until a
valid
Receiver 1 IP Address
is entered.
Receiver 1 Remote Port (Receiver 2 Remote Port)
Enter the Port number of the Main (Backup) Receiver
provided by the Central Station.
Default:
3061.
+
The
Receiver 2 Remote Port
is locked until a valid
Receiver 1 IP Address
is entered.
Supervision 1 Enabled (Supervision 2 Enabled)
If
enabled, the IP module periodically sends a Supervi-
sion Event to the Control Station and if it doesn’t receive
a response it generates a
System
>
IP Receiver 1 Lost
(
IP receiver 2 Lost
) Event.
Default:
disabled.
+
The
Supervision 2 Enabled
option is locked until
a valid
Receiver 2 IP Address
is entered.
Supervision Time 1 (Supervision Time 2)
Enter the
interval between an event and the subsequent supervi-
sion event.
Valid entries:
from 60 to 65,535 seconds.
Default:
60 seconds.
+
The
Supervision time 2
option is locked until a
valid
Receiver 2 IP Address
is entered.
e
In order to comply with the EN50136-2-1 stan-
dards, the
Supervision 1 Enabled
(
Supervision 2
Enabled
) option must be ENABLED and the
Su-
pervision Time 1
(
Supervision Time 2
) must not
exceed 180 sec.
Dynamic DNS Enabled
If this option is enabled it is
possible to reach the Control Panel router at the ad-
dress
<Serial Number>.absoluta.info
: see “KEYPAD
OPERATIONS > 3.2) View the Firmware Version” to
obtain the Control Panel serial number.
Absoluta Server Enabled
Enable this option to sup-
port:
Ø
the Remote Service via Internet (see “Down-
loading/Uploading > Connecting the Control Panel to
the PC)”;
Ø
the notification of events via e-mail (see “Smart Ac-
tions > Emails”);
Ø
the notification of events to the ABSOLUTA app (see
“Smart Actions > APP notification”);
ABSOLUTA Plus
PROGRAMMING FROM THE PC
93
20
To transmit events to IP receivers, the Contact ID and SIA protocols are encapsulated in the Fibro protocol and this
protocol requires its own Customer Code to identify the system transmitting the events
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...
Страница 98: ...98 Expandable Hybrid Control Panel...