Failed to access
The screen displays the following
message:
Ø
if you do not enter the valid PIN before the maximum
time of
60 seconds
;
Ø
If you enter an incorrect PIN;
Ø
Access to the Installer menu or Level 4 has not been
enabled.
+
The keypad locks for 90 seconds if 10 consecutive
invalid PINs are entered.
3
On Grade 3 panels, the keypad locks for 90 sec-
onds if 3 consecutive invalid PINs are entered.
View/Rest Alarms
The keypad shows the Alarms if
present:
*ALARM!
001/003
Zone
001
Ø
the
a
light ON indicates alarms in course;
Ø
the
a
light flashing indicates alarms in memory;
Ø
the display top line shows a flashing star (
*
) on the
left if the alarm is not longer present (Alarm Memory),
and the current alarm displayed respect to the total of
alarms, on the right;
Ø
the display bottom line shows the label of the zone in
alarm status.
7.
Press
ENTER
to skip “View/Reset Tampers”.
Press
A
to view the next alarm: if there are no more
alarms to view, the display shows the next available
events (tampers, faults or bypass) or the Partition
and System status.
Press
OFF
to reset the alarms.
ALARM Reset
Are you sure?
8.
Press
ENTER
to confirm.
ALARM Reset
Done !!
9.
Press
ESC
to view the next event.
View/Reset Tampers
The keypad shows the Tam-
pers if present:
*TAMPER! 001/003
Zone
001
*TAMPER! 001/003
Detector
01
Ø
the display top line shows a flashing star (
*
) on the
left if the tamper is not longer present (Memory), and
the current tamper displayed respect to the total of
tampers, on the right;
Ø
the display bottom line alternatively shows the label
of the object in tamper status and the tamper cause.
10.
Press
ENTER
to skip to “View/Reset Faults”.
Press
A
to view the next tamper: if there are no
more tampers to view, the display shows the next
available events (faults or bypass) or the Partition
and System status.
Press
OFF
to reset the tampers.
Clear Tamper
Are you sure?
11.
Press
ENTER
to confirm.
Clear Tamper
Done !!
12.
Press
ESC
to view the next event.
View Reset Faults
The keypad shows the Faults if
present:
FAULT!
001/003
Panel NO batt.
Ø
the display top line shows the current fault displayed
respect to the total of faults, on the right;
Ø
the display bottom line shows the fault label.
13.
Press
ENTER
to skip to “View Bypass”.
Press
A
to view the next fault: if there are no more
faults to view, the display shows the next available
events (bypass) or the Partition and System status.
Press
OFF
to reset the faults.
Clear Fault
Are you sure?
14.
Press
ENTER
to confirm.
Clear Fault
Done !!
15.
Press
ESC
to view the next event.
ABSOLUTA Plus
KEYPAD OPERATIONS
101