124
Expandable Hybrid Control Panel
EVENT
CONTACT ID
SIA
CL.CODE GROUP
ZONE
TYPE
1
st
2
nd
Surveillance Maintenance on panel
0
00
00
000
00
0000
000
Reset on Panel
4
06
00
000
BC
0000
000
Chime on Panel
0
00
00
000
00/00
0000
000
Negligence on Panel
6
54
00
000
CD
0000
000
Delinquency on Panel
3
00
00
000
UT
0000
000
Valid code on panel
4
22
00
000
JP
0000
000
Valid keyfob on Panel
4
22
00
000
JP
0000
000
Super key 1 on panel
0
00
00
000
00/00
0000
000
Super key 2 on panel
0
00
00
000
00/00
0000
000
Super key 3 on panel
0
00
00
000
00/00
0000
000
Keyfob Super key on panel
0
00
00
000
00/00
0000
000
Arm Refused on panel
4
54
00
000
CI
0000
000
Exit time on Panel
0
00
00
000
00/00
0000
000
Entry time on Panel
0
00
00
000
00/00
0000
000
Autoarming warning on Panel
0
00
00
000
00/00
0000
000
False key on panel
4
21
00
000
DD
0000
000
Memory alarm on panel
1
30
Part. n.
000
BA/BH
Part. n.
000
Remote Command
0
00
00
Code n.
00
Code n.
000
Caller ID over GSM
0
00
00
Tel. Num. n.
00
Tel. Num. n.
000
GSM Absence
3
00
00
TBD
00
TBD
000
GSM Link Lost
3
00
00
TBD
00
TBD
000
GSM Receiver 1 LOST
3
00
00
000
00
0000
000
GSM Receiver 2 LOST
3
00
00
000
00
0000
000
GSM - Cellular Network Fault
3
00
00
000
00
0000
000
Arming refused on command zones
4
54
00
Zone n.
CI
0000
Zone n.
Arming refused on keyfob
4
54
00
Keyfob n.
CI
0000
Keyfob n.
Duplicated and Discovered PIN
0
00
00
Code n.
00
0000
Code n.
User request service
0
00
00
Code n.
00
0000
Code n.
IP absence
3
00
00
000
YX/YZ
0000
000
IP link lost
3
00
00
000
YX/YZ
0000
000
IP remote lost
3
00
00
000
YX/YZ
0000
000
IP receiver 1 lost
3
00
00
000
YS/YZ
0000
000
IP receiver 2 lost
3
00
00
000
YS/YZ
0000
000
GSM Link Lost - Jamming/DoS
3
00
00
000
YX/YZ
0000
000
IP Link Lost - DoS
3
00
00
000
YX/YZ
0000
000
Loss of Time Trouble
3
00
00
000
YX/YZ
0000
000
Phone Line Fault - DoS Attack
3
00
00
000
YX/YZ
0000
000
Light Above High Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Light Below Low Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Temperature Above Very Hot Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Temperature Below Cold Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Temperature Below Freezing Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Temperature Above Freezer Threshold on Zone
0
00
00
Zone n.
00
0000
Zone n.
Low Voltage on Main Power*
3
01
00
000
AT/AR
0000
000
Low Voltage on Output 1*
3
02
00
000
YT/YR
0000
000
Low Voltage on Output 2*
3
02
00
000
YT/YR
0000
000
Low Voltage on Output 3*
3
02
00
000
YT/YR
0000
000
Table 22
Structure of the main Reporting formats supported by the System:
*)
this event is ONLY available on Grade
3 Control Panels and Grade 3 Power Stations.
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...
Страница 98: ...98 Expandable Hybrid Control Panel...