Reporting Formats
This paragraph describes the structures of the main re-
porting formats supported by the system.
+
Installer should customize codes for Superkey ac-
cording to customer (f.e. 1: Emergency, 2: Fire, 3:
Alarm). 000 means NO Communicate.
n
Contact ID
Contact ID transmits as follows.
Ø
User Code
(4 hexadecimal digits — 0 through F ).
Ø
Qualifier: 1
= new event or Disarming operation;
3
restore event or Arming operation.
Ø
Class Code
(
CL.
column): identifies the type of
event (Alarm, Trouble, Fire, etc.).
Ø
Reporting Code
(
CODE
column): identifies the
event (Reporting Codes can be changed, refer to
“Events and Actions” in the “PROGRAMMING
FROM THE PC” section).
+
00 means NO communication.
Ø
Group Number
(
GROUP
column), where possible,
identifies the Partition of the “resource” which gener-
ated the event.
Ø
Zone Number
(
ZONE
column), where possible,
identifies the “resource” (Zone, Code, Key, etc.)
which generated the event.
n
SIA
SIA is a FSK (Frequency Shift Keying) format, that trans-
mits alternatively in two slightly different frequencies.
The frequency shift is usually 170 Hertz, and the two fre-
quencies are associated with 0 and 1 of the binary digit
which transmits the following data:
Ø
User Code
(4 digits — 0 through 9)
Ø
Function Code
(1 digit; N=new event, O=restore event)
Ø
Date
(month-day-year)
Ø
Time
(hour-minutes-seconds)
Ø
Event Type
(refer to the
TYPE
column in Table 22)
Ø
Event Agent
(refer to the
1
st
and
2
nd
columns in Ta-
ble 22).
122
Expandable Hybrid Control Panel
EVENT
CONTACT ID
SIA
CL.CODE GROUP
ZONE
TYPE
1
st
2
nd
Alarm on zone
1
30
00
Zone n.
BA/BR
0000
Zone n.
Tamper on zone
1
37
00
Zone n.
TA/TR
0000
Zone n.
Fire alarm on partition
1
10
Part. n.
000
FA/FH
Part. n.
000
Low Battery on Wireless Detector
3
84
00
Detector n. XT/XR
0000
Detector n.
Partial arming partition
4
41
Part. n.
30
NL/OP
part. n.
30
Generic alarm on partition
1
30
Part. n.
000
BA/BH
part. n.
000
Tamper alarm on partition
1
37
Part. n.
000
TA/TR
part. n.
000
Global arming partition
4
00
Part. n.
30
CL/OP
part. n.
30
Disarming partition
4
00
Part. n.
30
OP/CL
part. n.
30
keyfob low battery
3
38
00
Keyfob n.
XT/XR
0000
Keyfob n.
Tamper on Main unit
1
37
00
000
TA/TR
0000
000
Service jumper
0
00
00
000
00/00
0000
000
Tamper on external siren
1
37
00
000
TA/TR
0000
000
Tamper on internal siren
1
37
00
000
TA/TR
0000
000
Tamper on Main unit (seize)
1
37
00
000
TA/TR
0000
000
Warning BPI peripheral
3
33
00
000
EM/EN
0000
000
Balanced tamper
1
37
00
000
TA/TR
0000
000
Warning fuse
3
00
00
000
YP/YQ
0000
000
Tamper BPI device
1
45
00
000
ES/EJ
0000
000
Schedule on Partition
0
00
00
000
00/00
0000
000
Wireless zone loss on Panel
3
81
00
000
BS/BR
0000
000
Wireless Receiver Tamper
1
45
00
000
ES/EJ
0000
000
Zone alarm on Panel
1
30
00
000
BA/BH
0000
000
Zone tamper on Panel
1
37
00
000
TA/TR
0000
000
System fault
3
00
00
000
BT/BJ
0000
000
Table 22
Structure of the main Reporting formats supported by the System (continued ...).
30
Transmits:
000
for the operation performed by the Command Zones and the Scheduler; the Identification Num-
ber of the PIN which produced the event (from
001
to
128
); the Identification Number, increased by
128
units, of the
Digital Key which produced the event (from
129
to
378
); the Identification Number, increased by
128 + 250
units, of
the keyfob which produced the event (from
379
to
394
). For example, if the event was produced by PIN no.1, 001 is
transmitted; if the event was produced by Digital Key no.1, 129 (1 + 128) is transmitted.