Connection via IP
The Figure 30 illustrates the principle of operation for
connection via IP between the ABSOLUTA Plus control
panel and the BOSS console.
n
Local IP connection (LAN)
With the local IP connection it is BOSS that connects to
the IP Module, as outlined below.
1.
If the
Obtain an IP address automatically
(
b3
) op-
tion is disabled, insert the
IP Address
(
b4
– default
192.168.0.101
) and the
Local BOSS Incoming
Port
(
b7
– default
3062
) for the IP Module in the
IP
(
a1
) and
Port
(
a2
) options respectively (see the
IP
options group).
2.
If the
Obtain an IP address automatically
(
b3
) op-
tion is ENABLED it is the router that assigns the IP
address to the IP Module. In this case, to obtain the IP
Module address select the
IP Status
option from the
Control Panel Keypad Installer Menu (option 3.5).
n
Remote IP Connection (Internet)
With the remote IP connection it is the IP Module that
connects to BOSS thanks to the
Absoluta Server
, as
outlined below.
1.
The IP Module communicates the Control Panel
Serial Number
(
d12
) to the
Absoluta Server
(
b6
)
(this
parameter
uniquely
identifies
every
ABSOLUTA Plus control panel).
2.
BOSS informs the
Absoluta Server
(
b6
) that it wants
to connect to the Control Panel with the
Serial Num-
ber d12
; see “PROGRAMMING FROM THE PC >
System Option > General > Serial Number” or
“KEYPAD OPERATIONS > 3.2) View the Firmware
Version” to obtain the Control Panel Serial Number.
126
Expandable Hybrid Control Panel
Internet
Router
Server Abso
server.absolut
ABSOLUTA
IP
Module
Other
Device
BOSS
1
2
b
IP
Option Group
3
4
7
6
5
a
Account Properties
Figure 30
Connection via IP.