ABSOLUTA Plus
PROGRAMMING FROM THE PC
73
EVENTS
OCCURS WHEN...
ENDS WHEN...
False Key Event
... a false Key is used on the Reader.
... the false Key has been removed from the
Reader.
Valid Key
... the Key is used on a Reader.
... the Key is removed from the Reader.
Valid Key on Key
Reader
... a valid Key is used on the Reader.
... the Key is removed from the Reader.
Valid Code
... arming, special arming, disarming or
ENTER
key is pressed after entry the User
PIN.
SPOT EVENT!
Valid Code on
Keypad
... arming, special arming, disarming or
ENTER
key is pressed after entry of a VALID
User PIN on the Keypad.
SPOT EVENT!
Invalid Code on
Keypad
... arming, special arming, disarming or
ENTER
key is pressed after entry of an
INVALID User PIN on the Keypad.
SPOT EVENT!
Super Key 1 on
keypad
... the Key
1
on the LCD Keypad (the Key
on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Super Key 2 on
keypad
... the key
2
on the LCD Keypad (the Key
on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Super Key 3 on
keypad
... the key
3
on the LCD Keypad (the Key
on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Valid Keyfob
... a button on the keyfob is pressed
SPOT EVENT!
Super Key on
Keyfob
... the
Q
button is pressed or, the away arming
and stay arming
buttons are pressed, si-
multaneously, for at least 2 seconds, on the
keyfob (1)
SPOT EVENT!
Keyfob Low
Battery
... the keyfob transmits a low battery message
to the transceiver (2).
... the keyfob transmits a charged battery mes-
sage to the transceiver.
Table 13
Key and PIN Events.
1)
The
Super Key Event
or
Arming Mode B + Super Key Event
function must be assigned to the auxiliary button
Q
, or to
the combination of away arming
button plus stay arming
button of the keyfob (see the option group
Users
>
Keyfobs
).
2)
The keyfob communicates the status of its battery along with each message sent to the transceiver.
EVENTS
OCCURS WHEN...
ENDS WHEN...
Exit Time on
Partition
...the Partition Arms in Stay or Away Mode.
... the Partition Exit Time expires.
Chime on
Partition
... a Zone with the
Chime
option belonging to
the Partition detects Alarm conditions when the
Partition is Disarmed.
SPOT EVENT!
Delinquency on
Partition
... the
Inactivity Time
expires.
SPOT EVENT!
Negligence on
Partition
... the
Negligence Time
expires.
SPOT EVENT!
Reset on
Partition
...
Alarms Reset
is requested using a User PIN
and Keypad jointly enabled for the Partition.
SPOT EVENT!
Table 12
Partition Events
Содержание Bentel Security tyco ABS128M50