Smart Actions
+
The communicator is disabled as long as there is a
PIN to default
fault, i.e., no communication action
is performed even if programmed (see “EN50136”
in “System Options > EN50131/EN50136”).
Smart Actions
are those which the Control Panel “con-
structs” automatically using system information, such
as object labels.
There are three types of
Smart Actions
:
Ø
Smart SMS
, to send SMS messages;
Ø
Emails
, to send e-mails;
Ø
APP Notification
, to send notification to telephones
with the ABSOLUTA app.
The
Smart Actions
options group is for programming
Smart Actions
as outlined below.
Events Categories
Displays the groups of events for
Smart Actions
that can be enabled, as outlined in the
following sections.
n
Smart SMS
To create
Smart SMS
messages BOSS uses the labels
assigned to system objects and various fixed strings, as
shown in the first row of Table 19 on page 80; the
square brackets ([]) show the alternatives separated
with the pipe symbol (|); double quotation marks (“”)
show fixed text; curly brackets () show the various text
options described below.
Ø
space
is the ‘space’ character.
Ø
Central Header
is
Message # 1 - Panel
in the
SMS
Messages
options group.
Ø
String for Reset
is the string that is shown if an
event is reset.
Ø
Type of Event
is a string relating to event type.
Ø
WHERE
is the label assigned to the device used to
generate the event.
Ø
WHO
is the label assigned to the subject that caused
the event.
Ø
Partitions
is the label assigned to the Partition in-
volved in the event, if an individual Partition is in-
volved, or the “Partition:<space>” string followed by
a 16-character string (8 for the ABSOLUTA Plus 18
and ABSOLUTA Plus 48 control panels) comprising
the ‘-’ character for Partitions NOT involved in the
event and the ‘X’ character for Partitions involved in
the event (e.g. the string —X——-X———- means
that Partitions 3 and 9 were involved).
Ø
Time and Date
are the event time and date with the
format set for the control panel (see “Date/Time
(2.4)” in the USER MANUAL).
Some examples of Smart SMS examples are outlined below:
Ø
Home
Zone alarm
KITCHEN
( first floor ) (
10:12:30
12/24/12
);
Ø
Home
RESTORAL
Zone alarm
KITCHEN (
first
floor
) (10:12:30 12/24/12);
Ø
Home
Zone
alarm
STAIRS
(
partitions:
X-X——————- );
Ø
Home
Valid
Key
DAD
READ.MAIN
DOOR
(
10:12:30 12/24/12
).
Where:
Ø
Home
is the Central Header;
Ø
Zone alarm
and
Valid Key
are Types of Event;
Ø
RESTORAL
is the string to reset the event;
Ø
KITCHEN
and
STAIRS
are the labels of WHO
caused the event;
Ø
first floor
is the Partition label involved;
Ø
partitions: X-X——————-
are the Partitions in-
volved (no. 1 and 3);
Ø
READ.MAIN DOOR
is the label of the WHERE ob-
ject that caused the event.
+
As the
ABS-GSM
supports SMS messages with a
maximum length of 160 characters the SMS may
be truncated.
+
To use this function the
ABS-GSM
Module must be
installed and programmed as outlined in the “GSM”
section.
+
By default, the Smart SMS related to an event is
sent to all telephone numbers of the
Type Voice
Dialer
of the
Phonebook
.
Select the phone numbers to send the Smart SMS to
using the
SMS
>
Vocal Numbers
of the
Events and
Actions
group of options.
All
If this option is ENABLED the Control Panel will
send a
Smart SMS
upon the verification and reset (for
events that allow reset) of ALL events belonging to the
corresponding group.
Default:
Disabled.
+
This option is disabled and locked if the
Only En-
abled in Events and Actions
option is ENABLED.
Only enabled in Events and Actions
If this option is
ENABLED the Control Panel will send a
Smart SMS
upon
the verification and reset (for events that allow reset) ONLY
of events belonging to the corresponding group that have
the
SMS Enabled
and
Restore via SMS
options
ENABLED (see the
Events and Actions
Options Group).
Default:
disabled.
+
This option is disabled and locked if the
All
option
is ENABLED.
+
This option is not available for the
System - Main
AC
,
System - Main LOW battery
,
System - Peri-
odic event
-
User request service
event groups
because these groups consist of only one event.
ABSOLUTA Plus
PROGRAMMING FROM THE PC
79
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...
Страница 98: ...98 Expandable Hybrid Control Panel...