Options EN50131/EN50136
Table 23 shows the options for EN50131 and EN50136
and the value they take when choosing
EN DEFAULT
ON
or
EN DEFAULT OFF
at startup of the panel, or
when the
ON
or
OFF
button is selected in the group
System Options
>
EN50131/EN50136
of the
BOSS
.
ABSOLUTA Plus
APPENDIX
125
Group button “System Option > EN50131/EN50136" of the BOSS
ON
OFF
Panel Startup
EN DEFAULT ON
EN DEFAULT OFF
Configuration > Keypad > EN50131
Enabled
Disabled
Configuration > KeyReader > EN50131
Enabled
Disabled
Zones
5 > Label
Faulty Zones
Zone
005
5 > Balance
Single End Of Line
Double End Of Line
5 > Type
Instant Zone, Zone
Fault
Instant Zone
6 > Label
Faulty Hold-up
Zone
006
6 > Balance
Single End Of Line
Double End Of Line
6 > Type
Instant Zone,
Hold-up, Zone Fault
Instant Zone
7 > Label
Faulty Int.siren
Zone
007
7 > Balance
Single End Of Line
Double End Of Line
7 > Type
Instant Zone, Fault
On Internal Siren
Instant Zone
8 > Label
Faulty Ext.siren
Zone
008
8 > Balance
Single End Of Line
Double End Of Line
8 > Type
Instant Zone,
External Siren Fault
Instant Zone
System Options > General
User Code Length
6 (cannot be changed)
from 4 to 6
Auto PIN Generation
Enabled (cannot be
changed)
Disabled
Main Board Wired Siren Squawk
Output
01
Disabled
Ignore Log Limit
Disabled
Enabled
Supervised Siren
Enabled
Disabled
Instant alarm notifications during entry time
Disabled
Enabled
System Options > Phone Options
Line check
Enabled
Disabled
Don’t Check Incoming Call
Disabled (cannot be
changed)
Disabled
Answering Machine Enabled Channels
GSM only (cannot be
changed)
PSTN and GSM
System Options > EN50131/EN50136
Refuse arming on incomplete exit condition
Enabled
Disabled
Refuse arming on Keyfob
Enabled
Disabled
Apply EN50131 to Scheduler
Enabled
Disabled
Refused arming on Command Zones
Enabled
Disabled
Apply EN 50131 to SMS arming
Enabled
Disabled
EN50136
Enabled
Disabled
Cellular Jamming/DoS Generates Fault
Enabled
Disabled
IP DOS Generates Fault
Enabled
Disabled
PSTN DoS Generates Fault
Enabled
Disabled
Show daylight saving fault
Enabled
Disabled
Table 23
Options EN50131/EN50136.