130
Expandable Hybrid Control Panel
Option
Description
Freezer: Wait
before alert
This option sets the time that the temperature measured by the device must be above the
temperature set in the
Freezer: Threshold
option, before
Temperature Above Freezer Threshold
on Zone
event occurs.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Freezer: Wait
before restore
This option sets the time that the temperature measured by the device must be at least 1°C
below the temperature set in the
Freezer: Threshold
option, before
Temperature Above Freezer
Threshold on Zone
event ends.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Freezing:
Threshold
This option sets the threshold for the freezing temperature alert. Event
Temperature Below
Freezing Threshold on Zone
occurs when the temperature measured by the device remains
below the temperature set in this option, for the time set in
Freezing: Wait before alert
option.
The event restores when the temperature measured by the device remains at least 1°C
above the temperature set in this option, for the time set in
Freezing: Wait before restore
op-
tion.
Optional settings: from -29°C to 39°C (default 7°C)
Freezing: Wait
before alert
This option sets the time that the temperature measured by the device must be below the
temperature set in the
Freezing: Threshold
option, before
Temperature Below Freezing Thresh-
old on Zone
event occurs.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Freezing: Wait
before restore
This option sets the time that the temperature measured by the device must be at least 1°C
above the temperature set in the
Freezing: Threshold
option, before
Temperature Below Freez-
ing Threshold on Zone
event ends.
Optional settings:
Fast
,
1 Minutes
,
2 Minutes
,
10 Minutes
(default),
15 Minutes
,
20 Minutes
, or
30 Minutes
.
Light High
Threshold
This option sets the threshold for the illuminance above threshold notice. Event
Light Above
High Threshold on Zone
occurs when the illuminance measured by the device exceeds the
illuminance set in this option. The event restores when the illuminance measured by the de-
vice drops below the illuminance set in this option.
Optional settings: from 0 lux to 65535 lux (default 1200 lux)
Light Low
Threshold
This option sets the threshold for the illuminance below threshold notice. Event
Light Below
Low Threshold on Zone
occurs when the illuminance measured by the device drops below the
illuminance set in this option. The event restores when the illuminance measured by the de-
vice exceeds the illuminance set in this option.
Optional settings: from 0 lux to 65535 lux (default 400 lux)
Reed Switch
If you enable this option, you can associate the reed switch of the device to a logical zone of
the control panel.
Optional settings: disabled, or enabled (default).
Refused
Arming/Disarming
Squawk
If you select
Sounder and Strobe
, the siren activates three times for arming and disarming re-
fused, due to blocking conditions.
Optional settings:
Disabled
, or
Sounder and Strobe
(default).
Shock
Accumulator
If you enable this option, the detector accumulates detected shocks when they are below the
value set in the
Shock Sensitivity
option. The detector goes into alarm when the accumulated
shocks reaches the value set in the
Shock Sensitivity
option. The detector resets accumula-
tion if one second expires since last shock detected, or 10 seconds expire since first shock
detected.
If you disable this option, the detector goes into alarm when it detects a single shock with
intensity greater than the value set in the
Shock Sensitivity
option.
Optional settings: disabled (default), or enabled.
Shock Sensitivity
This option sets the shock intensity that goes into alarm the detector.
Optional settings: from 1 to 19 (default 8).
Sounder Volume
This option sets the volume level of the sounder.
Optional settings:
Low
,
Medium
(default), or
High
.
Table 24