n
Common Features for all versions
Zones/outputs dynamic allocation
Each zone and
each output can be programmed as “Not used”. This
will allow the installer to have the maximum number of
zones even if an expander is not fully used. The panel
will build a correspondence between the number of a
zone and its physical location.
E.g. the zone nr. 7 can be located on expander nr. 1,
terminal T1, and the zone nr. 8 can be located on ex-
pander nr. 2, terminal T4.
On board Inputs
r
4 zones.
r
4 Programmable Terminals (Zones/Outputs).
r
Zones supervision (NC / NO / EOL / DEOL).
r
Fully-programmable input-zones.
r
1 supervised (10 Kohm EOL) 24h Tamper Zone.
On board outputs
r
1 Programmable Alarm Output 2 A relay (Bell output).
r
2 Programmable Open-Collector Outputs (100 mA
each).
r
4 Programmable Terminals (Zones/100 mA Outputs).
r
Fully Programmable Output options (polarity, Tim-
ing, Events, Timers).
r
Supervised Bell circuit.
Peripherals
ABSOLUTA
M-Touch,
ABSOLUTA
T-Line, LCD PREMIUM and CLASSIKA keypads, Ex-
pander M-IN/OUT module, PROXY2 and ECLIPSE2
Key readers, BXM12 Power supply stations.
+
When using the M-Touch keypad with control pan-
els based on the ABS-128 motherboard, do not
use more than 104 zones. The M-Touch keypad
may give unreliable indications for the zones be-
yond the 104 recommended.
Wireless
r
1 transceiver at 868 MHz.
Interfaces
r
BPI Plus bus (+12 V only).
r
Bus for
BW-PGH
transceiver.
r
PC-Link interface.
r
USB OnTheGo Device/Host.
Options AS100
2-way audio station for remote listen-
ing (speaker and microphone).
Communications
r
Integrated PSTN interface.
r
Phone Line monitoring.
r
Double Call.
r
Line-sharing Management.
r
Up to 32 telephone numbers for Voice/SMS Dialler
and Central Station.
r
Supports CONTACT ID and SIA Reporting Formats.
r
Programmable Test Call.
r
Remote servicing.
r
Periodic Transmission Test.
r
Integrated Voice Calls.
r
Up to 206 voice messages, total time 20.7 minutes.
r
Voice Guide by Telephone, with Remote DTMF de-
vice management.
r
Down-loadable Pre-Recorded Voice messages.
Features
ABS-18
ABS-48
ABS-128
Zones on Board (Min/Max)
4/8
Outputs on Board: Relay
1
Outputs on Board: Open Collector (Min/Max)
2/6
Max number of Zones (Wired plus Wireless)
18
48
128
Max number of Wireless Sirens (1)
16
16
16
Max number of Repeaters
8
8
8
Max number of Outputs
16
20
50
Max Number of Input Expanders
32
32
32
Max Number of Output Expanders
16
16
16
Max Number of Keypads
8
8
16
Max Number of User PINs
31
63
127
Installer PINs
1
Level 4 PINs
1
Max Number of Key Readers
16
32
32
Max Number of Keys
64
128
250
Max Number of Keyfobs
16
16
32
Max Number of Power Supply Stations
4
4
4
Max Number of Transceivers
1
Max Number of Audio Stations
1
GSM Module
1
IP Module
1
Partitions
8
8
16
Max Number of Events in Logger
2,000
Timers
16
Voice Messages
1 x 12 s 205 x 6 seconds
Telephone Numbers
32
Table 1
Characteristics of the various types of Control Panel:
1)
Each wireless siren can take up to four logic outputs,
one output for each siren sound, so the maximum number of sirens is limited by the maximum number of outputs.
Содержание Bentel Security tyco ABS128M50