Emails
The
Emails
Options Group is for the definition of the
e-mail addresses to be associated with Partitions and
System Events, for the notification of events via e-mail
(see “Smart Actions > Emails” for further information).
n
Addresses
The E-mail Address Subgroup is for the definition of
e-mail addresses to which events must be sent.
Label
Insert a meaningful description for the e-mail ad-
dress.
Valid entries
: up to 16 alphanumerical characters.
Default
: empty.
Address
Insert a valid e-mail address.
Valid entries
: up to 32 alphanumerical characters.
Default
: empty.
n
Partitions
The
Partitions
Subgroup is for the association of
e-mails, defined in the
Addresses
Subgroup, with Par-
titions.
Label
Shows the list of Control Panel Partitions and
the
System
label for system events.
E-mail Address 1/ E-mail Address 2
E-mail Address 1/ E-mail Address 2
Select the e-mail
addresses where events relating to the corresponding Par-
titions and System Events must be sent.
+
Up to 4 e-mail addresses can be selected for each
Partition and for System Events.
Users: Codes and Options
The User PIN allow the Users to access the system, by
a Keypad, by a DTMF telephone, by SMS and by the
BOSS’s
Status
Page.
+
PIN n. 1 CANNOT access the system by phone.
Each User PIN can be programmed to control specific
functions and Partitions.
PIN
The PIN is the combination of digits that allows ac-
cess to PIN functions. The PIN can be a 4 (Grade 2
Control Panels ONLY), 5 or 6 digit number.
Keypads and User PINs
Each Keypad and User PIN
can be programmed to control specific Partitions.
Therefore, the outcome of a command entered at a
Keypad depends on the User PIN and Keypad in use
(commands will affect ONLY the Partitions common to
both the User PIN and Keypad). This dual level of con-
trol greatly increases application flexibility, for example,
a PIN can be programmed to control a certain group of
Partitions when entered at one Keypad, and a different
group when entered at another. This feature simplifies
User control, as the same operation will have a different
outcome on different Keypads.
Valid PIN Event
Each time the Control Panel recog-
nizes a Valid PIN, it will generate the
Valid PIN
Event.
Like all other Control Panel Events, this Event can be as-
signed to an Output or Telephone Action — regardless of
whether or not the PIN is enabled to request Control
Panel actions. Therefore, an opportune combination of
Events and Outputs will eliminate some of the hitches
linked with access control and/or limitations.
PIN Transfer
The
PIN Transfer
option allows the in-
staller to upload or download the User PIN’s with a PC
connected serially to the control panel (USB or RS232),
by Internet/GPRS (with the optional
ABS-GSM
Mod-
ule), or using a USB key.
+
User PIN’s CANNOT be uploaded or downloaded
by phone because this type of connection does not
offer the security needed for this type of informa-
tion.
The User needs to enable
PIN Transfer
as described in
the section “LCD KEYPAD OPERATIONS > Program >
Enable Installer (Teleservice) (2.2)” of the USER MAN-
UAL then the installer should load the option
System
Options
>
General
>
Allow installer access personal
programming
.
+
When PIN Transfer is enabled, the installer can also
use the keypad to program ALL the numbers in the
Phone Book (see “LCD KEYPAD OPERATIONS >
2.8) Telephone Communicator”).
ABSOLUTA Plus
PROGRAMMING FROM THE PC
83
Содержание Bentel Security tyco ABS128M50
Страница 14: ...14 Expandable Hybrid Control Panel...
Страница 98: ...98 Expandable Hybrid Control Panel...