Emails
If this option is ENABLED the Control Panel will send
an e-mail
14
upon the verification (and reset) of the
events belonging to the corresponding group, to the
group of addresses (up to 4) programmed in the
Emails
Options Group, on the basis of the relevant
Partition for the event which has verified.
If the event does not belong to any Partition (System
Events) the e-mail will be sent to a group of specific ad-
dresses.
For example, if the Zone 1 Alarm occurs and Zone 1
belongs to Partitions 1 and 3, the e-mail will be sent to
the addresses defined for Partitions 1 and 3.
The
sender
of the e-mail will be “[email protected]”.
The
subject
of the e-mail will have the following for-
mat:
<Central Header>":"<space><Type of Event>
Where:
Ø
Central Header
is
Message # 1 - Panel
in the
SMS
Messages
options group.
Ø
Type of Event
will be:
—
Alarm
, for alarm events,
—
Tamper
, for tamper events,
—
Fault
, for fault events,
—
Generic
, for all other events,
—
Restore Alarm
, for alarm reset events,
—
Restore Tamper
, for tamper reset events,
—
Restore Fault
, for fault reset events,
—
Restore Generic
, for the reset of all other
events.
The
body
of the e-mail will show the information relat-
ing to the event, in the same format as
Smart SMS
messages (see “Smart SMS” for further information).
The subject and body of the e-mail may show infor-
mation for several events, if they occurred within
20
seconds
of the first event.
+
To use this function the
ABS-IP
Module must be in-
stalled and programmed as outlined in the “IP” section.
Default:
Disabled.
n
APP Notification
If this option is ENABLED the Control Panel will send
notification upon the verification (and reset) of the
events belonging to the corresponding group, to the
telephones that have the ABSOLUTA app installed.
+
Users with the ABSOLUTA app installed on their
telephones must enable them to receive notifica-
tion via the relevant option.
User will receive notification of events relating to their
PIN and the Partitions on which it is enabled in addition
to System Events (if selected).
The
Master
user (see
User Type
in the
Users
>
Codes
and Options
option group) can disable the function to
receive notification for all telephones registered.
When users receive notification they can click on the rel-
evant icon to see event information: information will
have the same format as the Smart SMS messages (see
“Smart SMS” for further information).
+
To use this function the
ABS-IP
Module must be in-
stalled and programmed as outlined in the “IP” section.
Default:
disabled.
n
Partitions
This option makes it possible to filter Smart Actions, ex-
cept those of the system, based on the partitions: the
Smart Action is executed ONLY when the event that
generated it has at least one Partition in common with
the Smart Action.
Select the Smart Action partitions.
+
At least one partition must be selected for each
Smart Action.
Default:
all partitions.
14
The Control Panel will send the information to a remote server (server.absoluta.info) via the
ABS-IP
Module with
128-bit AES encryption; the remote server will create a HTML message with the information received to be
forwarded to the programmed e-mail addresses.