Expandable Hybrid Control Panel
EVENTS
OCCURS WHEN...
ENDS WHEN...
General System
Alarm
... a Zone — regardless of its Type and Parti-
tion detects Alarm conditions.
... ALL events generated by the zones of all
Partitions restore to standby
.
General System
Tamper
... a zone — regardless of its partition detects
tamper conditions, or a repeater, a wireless si-
ren, or the transceiver, is tampered or lost.
... ALL tamper events generated by the zones
of all partitions restore to standby, and ALL
tamper events of all repeaters, all wireless si-
rens, and of the transceiver, restore to standby.
Low Battery on
Wireless
Detectors
... one of the
Low Battery on Wireless Detector
events occurs (see Table 11 on page 72).
... ALL
Low Battery on Wireless Detector
events
end (see Table 11 on page 72).
Tamper on Main
Unit
... the Control Panel Tamper switch opens.
... the Tamper switch restores.
Service Jumper
... the SERVICE jumper is inserted
... the SERVICE jumper is removed.
Tamper on
External Siren
...
External Siren Tamper
is set for the
Panel
AS Tamper
option AND the
AS
terminal is un-
balanced.
…
External Siren Tamper
is set for the
Panel
AS Tamper
option AND the [AS] terminal is bal-
anced (grounded with a 10,000 ohm resistor).
Fault on
External Siren
... the external siren fails.
... ALL the fault conditions on the external siren
restore.
Tamper on
Internal Siren
... the supervised output is tampered.
... the Output tamper event ends.
Fault on Internal
Siren
... the internal siren fails.
... ALL the fault conditions on the internal siren
restore.
Tamper BPI
Device
... a BPI Device Tamper switch or Wall-Tamper
switch open.
... all BPI Device Tamper switches and
Wall-Tamper switches restore.
Wireless
Receiver Tamper
... the transceiver is opened or removed from
the mounting surface, or when the transceiver
detects RF jamming.
... the transceiver is closed and properly fixed
to the mounting surface, and does not detect
any RF jamming.
Warning BPI
peripheral
... an enrolled BPI peripheral does not respond
to the Control Panel.
... ALL the BPI peripherals respond to the Con-
trol Panel.
WLS Receiver
Lost
... the transceiver does not respond to the con-
trol panel.
... the transceiver responds to the control
panel.
Warning Fuse
... at least one of the power terminals on the
Main Board (
+F
,
+B
,
+BPI
,
RED
) is over-
loaded.
... the current drawn by the power terminals on
the Main Board (
+F
,
+B
,
+BPI
,
RED
) drops be-
low the permitted limit.
Warning Mains
Failure
...Mains power has been off for the pro-
grammed Timeout (refer to "Options").
... Mains power is restored.
Warning Low
Battery
... Battery voltage drops below 11.4 V.
... Battery voltage is restored to 12.3 V.
Battery Power
Trouble
... a Battery fails the Dynamic Test (refer to
"Connecting
the
Power
supply"
under
"INSTALLING"), or fuse blows.
... Battery meets the Dynamic Test require-
ments, and fuse is replaced.
Telephone Line
Trouble -
General
... the Telephone Line voltage is less than 3 V
for 45 seconds. If the
Line check
is disabled
(refer to "Phone Options"), the event cannot
be generated.
... the Telephone Line voltage is higher than
3 V for 45 seconds.
Telephone Line
Trouble - DoS
... the option
PSTN DoS Generates Fault
of the
group
System Options
>
EN50131/EN50136
is
ENABLED and the panel detects a DoS attack
on the PSTN interface.
... the option
PSTN DoS Generates Fault
of the
group
System Options
>
EN50131/EN50136
is
ENABLED and the panel does NOT detect any
DoS attack on the PSTN interface.
Warning Mains
Failure on
Power Station
... the programmed Timeout expires (refer to
"Power stations" under “Configuration”). The
Timeout will start when the Control Panel de-
tects failure of the Mains supply — to one of the
BPI Bus Power Supply Stations.
... Mains power is restored to ALL the BPI Bus
Power Supply Stations.
Warning Low
Battery on
Power Station
... the Battery Voltage of a BPI Power Supply
Station drops below 11.4V.
... the Battery voltage of ALL BPI Power Supply
Stations restores to 12.3V.
Table 14
System Events (continued on next page).