CHV100 Series Close Loop Vector Control Inverter
.32.
Terminal
Description
Input impedance: 3.3k
Ω
HDI1
(
HDI2
)
High speed pulse or ON-OFF signal input, optical coupling with PW
and COM.
Pulse input frequency range: 0~50kHz
Input voltage range: 9~30V
Input impedance: 1.1k
Ω
PW
External power supply. +24V terminal is connected to PW terminal
as default setting. If user need external power supply, disconnect
+24V terminal with PW terminal and connect PW terminal with
external power supply.
+24V
Provide output power supply of +24V.
Maximum output current: 150mA
AI1
(
AI3
,
AI4
)
Analog input, 0~10V
Input impedance: 10k
Ω
AI2
Analog input, 0~10V/ 0~20mA, switched by J18.
Input impedance:10k
Ω
(voltage input) / 250
Ω
(current input)
GND
Common ground terminal of analog signal and +10V.
GND must isolated from COM.
Y1
(
Y2
)
Open collector output terminal, the corresponding common ground
terminal is CME.
External voltage range: 0~24V
Output current range: 0~50mA
The range of 24V pull-up resistor: 2k
~
10k
Ω
CME
Common terminal of open collector output
COM
Common ground terminal for digital signal and +24V (or external
power supply).
+10V
10V for inverter.
HDO
High speed pulse output terminal. The corresponding common
ground terminal is COM.
Output frequency range: 0~50 kHz
AO1
(
AO2
)
Provide voltage or current output which can be switched by J19.
Output range: 0~10V/ 0~20mA
PE
Ground Terminal.
RO1A
、
RO1B
、
RO1 relay output: RO1A
—
common; RO1B
—
NC; RO1C
—
NO.