CHV100 Series Close Loop Vector Control Inverter
.144.
Function
Code
Name
Description
Factory
Setting
Modify LCD Display
PA.32
Multi-step speed
15
-100.0~100.0%
0.0%
○
MULTI-SPEE
D 15
PA.33
15
th
Step running
time
0.0~6553.5s(h)
0.0s
○
RUNNING
TIME 15
PA.34
ACC/DEC time
selection for step
0~7
0~65535
0
○
0~7 TIME
SELECT
PA.35
ACC/DEC time
selection for step
8~15
0~65535
0
○
8~15 TIME
SELECT
PA.36
Time unit
0: Second
1: Hour
0
◎
TIME UNIT
PB Group: Protection Function
PB.00
Input
phase-failure
protection
0: Disabled
1: Enabled
1
○
IN PHASE
FAIL
PB.01
Output
phase-failure
protection
0: Disabled
1: Enabled
1
○
OUT PHASE
FAIL
PB.02
Motor overload
protection
0: Disabled
1: Normal motor
2: Variable frequency
motor
2
◎
MOTOR
OVERLOAD
PB.03
Motor overload
protection current
20.0%~120.0%
100.0%
○
OVERLOAD
CURR
PB.04
Overload
pre-warning
threshold
20.0%~150.0%
130.0%
○
OL WARN