CHV100 Series Close Loop Vector Control Inverter
.26.
Braking unit
Braking resistor
(100% braking torque)
Model No.
Order No.
Quantity
Specification
Quantity
3AC 380V
±
15%
CHV100-1R5G-4
400
Ω
/260W
1
CHV100-2R2G-4
CHV100-004G-4
150
Ω
/390W
1
CHV100-5R5G-4
100
Ω
/520W
1
CHV100-7R5G-4
CHV100-011G-4
50
Ω
/1040W
1
CHV100-015G-4
Build- in
1
40
Ω
/1560W
1
CHV100-018G-4
CHV100-022G-4
CHV100-030G-4
20
Ω
/6000W
1
CHV100-037G-4
CHV100-045G-4
CHV100-055G-4
DBU-055-4
1
13.6
Ω
/9600W
1
CHV100-075G-4
CHV100-090G-4
CHV100-110G-4
DBU-055-4
2
13.6
Ω
/9600W
2
CHV100-132G-4
CHV100-160G-4
DBU-160-4
1
4
Ω
/30000W
1
CHV100-185G-4
CHV100-200G-4
CHV100-220G-4
DBU-220-4
1
3
Ω
/40000W
1
CHV100-250G-4
CHV100-280G-4
CHV100-315G-4
DBU-315-4
1
3
Ω
/40000W
2
Notice:
1.
Above selection is based on following condition: 700V DC braking voltage
threshold, 100% braking torque and 10% usage rate.
2.
Parallel connection of braking unit is helpful to improve braking capability.
3.
Wire between inverter and braking unit should be less than 5m.
4.