CHV100 Series Close Loop Vector Control Inverter
.120.
Function
Code
Name
Description
Factory
Setting
Modify LCD Display
P0.03
Frequency A
command source
0: Keypad
1: AI1
2. AI3
3: HDI1
4:Simple PLC
5. Multi-Step speed
6: PID
7: Communication
0
◎
FREQ
SOURCE A
P0.04
Frequency B
command source
0:AI2
1:AI4
2:HDI2
0
◎
FREQ
SOURCE B
P0.05
Scale of
frequency B
command
0: Maximum frequency
1: Frequency A command
0
○
FREQ B
SCALE
P0.06
Frequency
command
selection
0: A
1: B
2: A+B
3: Max
(
A, B
)
0
○
FREQ
SELECTION
P0.07
Maximum
frequency
10.0~400.00Hz
50.00Hz
◎
MAX FREQ
P0.08
Upper frequency
limit
P0.09~P0.07
50.00Hz
○
UP FREQ
LIMIT
P0.09
Lower frequency
limit
0.00Hz~ P0.08
0.00Hz
○
LOW FREQ
LIMIT
P0.10
Keypad reference
frequency
0.00 Hz ~ P0.08
50.00Hz
○
KEYPAD
REF FREQ
P0.11
Acceleration time
0
0.0~3600.0s
20.0s
○
ACC TIME 0
P0.12
Deceleration time
0
0.0~3600.0s
20.0s
○
DEC TIME 0
P0.13
Running direction
selection
0: Forward
1: Reverse
2: Forbid reverse
0
◎
RUN