CHV100 Series Close Loop Vector Control Inverter
.60.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P2.03
Motor rated
voltage
0~3000V
0~3000
Depend
on model
P2.04
Motor rated
current
0.1~2000.0A
0.1~2000.0
Depend
on model
P2.05
Motor rated power
1.5~900.0kW
1.5~900.0
Depend
on model
Notice:
l
In order to achieve superior performance, please set these parameters
according to motor nameplate, then perform autotuning.
l
The power rating of inverter should match the motor. If the bias is too big,
the control performances of inverter will be deteriorated distinctly.
l
Reset P2.05 can initialize P2.06~P2.10 automatically.
Function
Code
Name
Description
Setting
Range
Factory
Setting
P2.06
Motor stator
resistance
0.001~65.535
Ω
0.001~65.535
Depend
on model
P2.07
Motor rotor
resistance
0.001~65.535
Ω
0.001~65.535
Depend
on model
P2.08
Motor leakage
inductance
0.1~6553.5mH
0.1~6553.5
Depend
on model
P2.09
Motor mutual
inductance
0.1~6553.5mH
0.1~6553.5
Depend
on model
P2.10
Current without
load
0.01~655.35A
0.01~655.35
Depend
on model
After autotuning, the value of P2.06~P2.10 will be automatically updated.
Notice: Do not change these parameters, otherwise it may deteriorate the control
performance of inverter.
6.4 P3 Group--Vector Control
Function
Code
Name
Description
Setting
Range
Factory
Setting
P3.00
ASR proportional
gain K
p
1
0~100
0~100
20