iManager NetEco 6000
Device Installation and Commissioning Guide
6 Adding Devices
Issue 03 (2019-03-10)
Copyright © Huawei Technologies Co., Ltd.
122
6
Adding Devices
Context
Software installation and commissioning are required before the device commissioning,
collector commissioning, and NetEco commissioning. Log in to
http://support.huawei.com
,
search for
iManager NetEco 6000 Product Documentation
, and commission the software
by referring to relevant sections in
NetEco Software Installation and Commissioning
Guide
.
For single-server scenarios, see the
iManager NetEco 6000 Product Documentation
.
For double-server scenarios, see the
iManager NetEco 6000 High Availability System Product
Documentation
.
Table 6-1
Encryption algorithms
Insecure Encryption Algorithm
Secure Encryption Algorithm
DES/3DES (excluding the scenario in
which K1≠K2≠K3 is used)
SKIPJACK
RC2
RSA (1024 bits or less)
MD2/MD4
MD5 needs to be used in the
scenarios where digital signatures are
generated or passwords are encrypted
before saving
SHA1 needs to be used in the
scenario where digital signatures are
generated
Symmetric encryption algorithm: AES (128
bits or more)
Asymmetrical encryption algorithm: RSA
(2048 bits or more)
Hash algorithm: SHA2 (256 bits or more)
Hashed message authentication code
(HMAC): HMAC-SHA2
Table 6-2
Communications protocols
Insecure Communications Protocol Secure Communications Protocol
SNMP V1/V2
SNMP V3